Promote quantitative ischemia imaging via myocardial perfusion CT iterative reconstruction with tensor total generalized variation regularization.

Phys Med Biol

School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, People's Republic of China. Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou 510515, People's Republic of China. These authors contributed equally.

Published: June 2018

Myocardial perfusion computed tomography (MPCT) imaging is commonly used to detect myocardial ischemia quantitatively. A limitation in MPCT is that an additional radiation dose is required compared to unenhanced CT due to its repeated dynamic data acquisition. Meanwhile, noise and streak artifacts in low-dose cases are the main factors that degrade the accuracy of quantifying myocardial ischemia and hamper the diagnostic utility of the filtered backprojection reconstructed MPCT images. Moreover, it is noted that the MPCT images are composed of a series of 2/3D images, which can be naturally regarded as a 3/4-order tensor, and the MPCT images are globally correlated along time and are sparse across space. To obtain higher fidelity ischemia from low-dose MPCT acquisitions quantitatively, we propose a robust statistical iterative MPCT image reconstruction algorithm by incorporating tensor total generalized variation (TTGV) regularization into a penalized weighted least-squares framework. Specifically, the TTGV regularization fuses the spatial correlation of the myocardial structure and the temporal continuation of the contrast agent intake during the perfusion. Then, an efficient iterative strategy is developed for the objective function optimization. Comprehensive evaluations have been conducted on a digital XCAT phantom and a preclinical porcine dataset regarding the accuracy of the reconstructed MPCT images, the quantitative differentiation of ischemia and the algorithm's robustness and efficiency.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/aac7bdDOI Listing

Publication Analysis

Top Keywords

mpct images
16
myocardial perfusion
8
tensor total
8
total generalized
8
generalized variation
8
mpct
8
myocardial ischemia
8
reconstructed mpct
8
ttgv regularization
8
ischemia
5

Similar Publications

Objective: To develop an ensemble machine learning (eML) model using multiphase computed tomography (MPCT) for distinguishing between gastric ectopic pancreas (GEP) and gastric stromal tumors (GIST) in lesions < 3 cm.

Methods: In this study, we retrospectively collected MPCT images from 138 patients between April 2017 and June 2023 across two centers. Cohort 1 comprised 94 patients divided into a training cohort and an internal validation cohort, while the 44 patients from Cohort 2 constituted the external validation cohort.

View Article and Find Full Text PDF

Higher pelvic incidence values are a risk factor for trans-iliac trans-sacral screw malposition in sacroiliac complex fracture treatment.

J Orthop Traumatol

September 2023

Division of Orthopedic Traumatology, Department of Orthopedic Surgery, Chang Gung Memorial Hospital, No. 5, Fu-Hsing Street, Kweishan 333, Taoyuan, Taiwan.

Background: Percutaneous iliosacral (IS) screw fixation and trans-iliac trans-sacral (TITS) screw fixation are clinically effective treatments of posterior pelvic sacroiliac fractures. In order to accurately assess the sacrum position relative to the pelvis, pelvic incidence (PI) is a commonly utilized radiographic parameter in sagittal view. This study aimed to investigate and compare the surgical outcomes and radiographic parameters of IS or TITS screw fixations for the treatment of posterior sacroiliac complex fractures with different PI values.

View Article and Find Full Text PDF

Multi-phase computed tomography (CT) images have gained significant popularity in the diagnosis of hepatic disease. There are several challenges in the liver segmentation of multi-phase CT images. (1) Annotation: due to the distinct contrast enhancements observed in different phases (i.

View Article and Find Full Text PDF

Objectives: We sought to examine the contribution of routine ultrasound when performed with computed tomography in identifying exclusion criteria in potential living kidney donors.

Methods: We performed a 10-year retrospective cohort study including all cases of potential renal donors at our center. For each case, the donor workup ultrasound (US) and multiphase computed tomography (MPCT) original reports and imaging were reviewed by a fellowship-trained abdominal radiologist in consultation with a transplant urologist and placed into one of 3 groups: (1) no significant US contribution, (2) US was useful to characterize an incidental finding (either US exclusive or US aided in CT interpretation) but did not impact donor eligibility, and (3) an US exclusive finding contributed to donor exclusion.

View Article and Find Full Text PDF

Introduction: Multiphase MRI liver is the gold-standard imaging modality for staging hepatocellular carcinoma (HCC) in patients with cirrhosis. Often, small HCCs diagnosed on multiphase MRI are occult on B-mode ultrasound and multiphase CT (MPCT) and thus pose a challenge for loco-regional therapy. We adapted the technique of lipiodol CT in treating two such patients of small HCC.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!