After publication of the original article [1], it was noticed that the Acknowledgement statement was incorrect. The original statement reads.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5968585 | PMC |
http://dx.doi.org/10.1186/s12859-018-2202-6 | DOI Listing |
PLoS One
January 2025
Electrical, Mechanical & Computer Engineering School, Federal University of Goias, Goiania, Brazil.
This paper proposes the use of artificial intelligence techniques, specifically the nnU-Net convolutional neural network, to improve the identification of left ventricular walls in images of myocardial perfusion scintigraphy, with the objective of improving the diagnosis and treatment of coronary artery disease. The methodology included data collection in a clinical environment, followed by data preparation and analysis using the 3D Slicer Platform for manual segmentation, and subsequently, the application of artificial intelligence models for automated segmentation, focusing on the efficiency of identifying the walls of the left ventricular. A total of 83 clinical routine exams were collected, each exam containing 50 slices, which is 4,150 images.
View Article and Find Full Text PDFIndian J Thorac Cardiovasc Surg
February 2025
Dept of CTVS, NEIGRIHMS, Shillong, India.
Isolated right superior vena cava (RSVC) drainage into the left atrium (LA) is a rare congenital anomaly, presenting diagnostic and management challenges. This study presents two cases of isolated RSVC drainage into the LA alongside a comprehensive literature review to improve understanding and delineate optimal surgical approaches. The study describes two cases of isolated RSVC drainage into the LA and their surgical management.
View Article and Find Full Text PDFUpdates Surg
January 2025
Division of General Surgery, Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy.
The standardization of preoperative imaging in primary hyperparathyroidism is one of the current challenges of endocrine surgery. A correct localization of the hypersecretory gland by neck ultrasound and 99mTc-sestamibi (MIBI) scintigraphy are not sufficiently sensitive in some cases. In recent years, CT-4D, 18F-Fluorocholine PET/CT, and radio-guided parathyroidectomy have come into common use.
View Article and Find Full Text PDFExp Appl Acarol
January 2025
Department of Agricultural Entomology, Tamil Nadu Agricultural University, Coimbatore, Tamil Nadu, 641003, India.
Parasit Vectors
January 2025
Environmental Health Directorate, Western Australia Department of Health, 37 Kensington Street, East Perth, Perth, Western Australia, 6004, Australia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!