Background: Pulmonary function testing is commonly performed for diagnosis and clinical management of respiratory diseases. It is important to use appropriate reference equations from healthy subjects for interpretation of data from infants with lung disease. This study aimed to determine if published reference equations were similar to forced flow measures and plethysmographic infant pulmonary function testing data collected in the Canadian Healthy Infant Longitudinal Development (CHILD) Study.
Methods: Reference equations for five pulmonary function variables (FEV , FVC, FEF , FEV /FVC ratio and plethysmography (FRC )) were developed using data from the nSpire system. New reference equations developed using healthy data from the CHILD Study were compared to previously published reference equations for forced flow and plethysmographic measures.
Results: The current analysis included 131 infants (on 181 test occasions) with forced flow measures and 161 infants (on 246 test occasions) with plethysmography measures, aged 3-24 months. Age and length were major determinants of both forced flow and plethysmography measures. In addition, ethnicity (Caucasian vs non-Caucasian) was significantly associated with FEV /FVC and FEF measures. We found that the published reference equations based on custom-built equipment or commercially available systems provided poor fit to our current pulmonary function testing data, resulting in placing a large proportion of our healthy population outside the normal ranges.
Conclusions: Our current data support the need for population and device specific reference data for infant pulmonary function studies. By deriving new equipment-specific reference equations for our healthy population, we provide normative data to other centers utilizing this equipment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ppul.24063 | DOI Listing |
Sensors (Basel)
January 2025
College of Geodesy and Geomatics, Shandong University of Science and Technology, Qingdao 266590, China.
Underwater acoustic transducers need to expand the coverage of acoustic signals as much as possible in most ocean explorations, and the directivity indicators of transducers are difficult to change after the device is packaged, which makes the emergence angle of the underwater acoustic transducer limited in special operating environments, such as polar regions, submarine volcanoes, and cold springs. Taking advantage of the refractive characteristics of sound waves propagating in different media, the directivity indicators can be controlled by installing an acoustic lens outside the underwater acoustic transducer. To increase the detection range of an underwater acoustic transducer in a specific marine environment, a curvature-determining method for the diverging acoustic lens of an underwater acoustic transducer is proposed based on the acoustic ray tracing theory.
View Article and Find Full Text PDFInsects
January 2025
International Centre for Advanced Mediterranean Agronomic Studies of Bari (CIHEAM Bari), 70010 Valenzano, Italy.
This study explored the thermal response of , an injurious insect pest present in many countries worldwide, at different controlled conditions. This species is responsible for several economic losses in soft fruit cultivations, develops on ripening fruits, and has the capability to quickly adapt to new territories and climates, closing multiple generations per year. Given its high invasive potential and the increasing need for low-impact control strategies, an in-depth exploration of the biology of this species and of the stage thermal response is fundamental.
View Article and Find Full Text PDFAnimals (Basel)
January 2025
School of Ecology and Nature Conservation, Beijing Forestry University, Beijing 100083, China.
This study analyzed survey result data of giant panda populations and habitats in the third and fourth giant panda surveys to reveal the population size-habitat area relationship and assess the habitat status at the county and nature reserve levels. Results showed that a significant linear relationship existed between the logarithm of population size (lnS) and the logarithm of habitat area (lnA), with an equation of lnS = 1.145 × lnA - 4.
View Article and Find Full Text PDFSci Rep
January 2025
Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, India.
The local pulse wave velocity (PWV) from large elastic arteries and its pressure-dependent changes within a cardiac cycle are potential biomarkers for cardiovascular risk stratification. However, pulse wave reflections can impair the accuracy of local PWV measurements. We propose a method to measure pressure-dependent variations in local PWV while minimizing the influence of pulse wave reflections.
View Article and Find Full Text PDFExpert Rev Respir Med
January 2025
Medical Sciences Post-Graduation Programme, School of Medical Sciences, State University of Rio de Janeiro (UERJ), Rio de Janeiro, Brazil.
Introduction: Technological advances have led to the proliferation of lung function assessment techniques beyond spirometry in most countries. At the same time, new knowledge of respiratory physiology has allowed an expansion of lung function parameters, requiring an integrated approach to interpreting results.
Areas Covered: This review addresses the major pulmonary function tests (PFTs) used in clinical practice, new concepts regarding reference values, and reformulations of terminology for defining standards of lung function impairment.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!