Significance: New bitangential mini-scleral lens designs provide a highly precise fit, follow the scleral shape, are comfortable to wear, and can correct residual astigmatism. This new scleral lens design complements the arsenal of medical contact lenses available to eye care practitioners.
Purpose: The aim of this study was to evaluate the subjective and objective performance of a new mini-scleral lens design with a bitangential periphery.
Methods: In this observational study, data were collected for up to 15 months (median, 84 days; interquartile range, 76 days) from the left eyes of 133 patients fitted with this newly designed lens. Data were recorded during regular visits at Visser Contact Lens Practice's scleral lens clinics: diagnosis, clinical indication for scleral lenses, previous contact lens type, subjective performance, horizontal visible iris diameter, corrected distance visual acuity, and scleral lens fitting characteristics.
Results: The most common indication was keratoconus (45%), followed by irregular astigmatism (22%), keratoplasty (16.5%), ocular surface disease (13.5%), and other forms of irregular astigmatism (3%). The majority of patients (79%) scored comfort as either a 4 or 5 (out of 5), and 82% wore their lenses 12 hours or longer a day. Most lenses (81%) had a diameter of 16 mm (median, 16 mm; range, 15.5 to 17 mm) and were composed of Boston XO2 (46%), Menicon Z (44%), Boston XO (9%), or Boston Equalens II (1%). The median corrected distance visual acuity was 0.022 logarithm of the minimal angle of resolution (interquartile range, 0.155). The fitting characteristics revealed optimal values for centration and movement in 91% and 83%, respectively. Finally, the median stabilization axis was 50 degrees.
Conclusions: New mini-scleral lenses with bitangential peripheral geometry yield satisfactory clinical results and good subjective performance and are therefore an effective option for managing patients who have irregular astigmatism or other corneal pathology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/OPX.0000000000001228 | DOI Listing |
Sci Rep
October 2024
Eye Center, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Graft-versus-Host disease is a major complication of allogeneic stem cell transplantation. The eyes are a frequently affected organ with a severe dry eye disease being the hallmark manifestation. This retrospective study evaluates the effect of mini-scleral contact lenses on visual acuity, eye-related quality of life and the ocular surface.
View Article and Find Full Text PDFCont Lens Anterior Eye
August 2024
University of Health Sciences, Haydarpasa Numune Training and Research Hospital, Department of Ophthalmology, Istanbul, Turkey.
J Fr Ophtalmol
October 2024
ELZA Institute, Dietikon, Zurich, Switzerland; Ocular Cell Biology Group, Center for Applied Biotechnology and Molecular Medicine, University of Zurich, Zurich, Switzerland; USC Roski Eye Institute, University of Southern California, Los Angeles, CA, USA; Department of Ophthalmology, Wenzhou Medical University, Wenzhou, China.
Purpose: To present a case series of patients with corneal scars who were successfully fitted with mini scleral contact lenses (mSCL).
Methods: Case series study.
Results: Six eyes of six patients with corneal scars were fitted with mSCLs.
Eye Contact Lens
August 2024
Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India .
Objectives: To evaluate the visual outcome of mini-scleral contact lenses (MSLs) in keratoconus following the resolution of acute hydrops.
Methods: This was a prospective observational case series of patients of healed hydrops in keratoconus fitted with an MSL (Keracare, Acculens, Lakewood, CO) who were managed for acute hydrops medically or surgically at least 3 months prior. Uncorrected visual acuity, best spectacles-corrected visual acuity, best lens-corrected visual acuity, topographic indices, keratometric indices, contact lens parameters, and ocular aberrometric changes were evaluated.
Eye Contact Lens
November 2023
Department of Ophthalmology (B.B., J.B., C.K., S.N.D.), Antwerp University Hospital, Edegem, Belgium; Faculty of Medicine and Health Sciences (B.B., C.K., S.N.D.), University of Antwerp, Wilrijk, Belgium; Department of Medical Biochemistry (S.R., H.C.A., T.P.U.), Oslo University Hospital, Oslo, Norway; Department of Plastic and Reconstructive Surgery (S.R., T.P.U.), Oslo University Hospital, Oslo, Norway; and Department of Applied Physics (A.C.), University of Zaragoza, Zaragoza, Spain.
Objectives: The aim of this prospective study is to examine the effects of 5 hours of well-fitted, mini-scleral contact lens (mini-SL) wear on the tear film cytokine expression in healthy eyes.
Methods: Twenty-three healthy participants were included in the study. One eye of each participant was selected at random, and a mini-SL measuring 16.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!