Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In this research, a new vortex assisted dispersive liquid-liquid microextraction based on the freezing of deep eutectic solvent (VADLLME-FDES) has been developed for the determination of organic mercury (R-Hg) and inorganic mercury (Hg) in blood samples prior to their analysis by graphite furnace atomic absorption spectrometry (GFAAS). In this method, a green solvent consisting of 1-octyl-3-methylimidazolium chloride and 1-undecanol was used as an extraction solvent, yielding the advantages of material stability, low density, and a suitable freezing point near room temperature. Under the optimum conditions, enrichment factor is 112. The calibration graph is linear in the range of 0.30-60 µg L and limit of detection (LOD) is 0.10 µg L. Repeatability and reproducibility of the method based on seven replicate measurements of 5.0 µg L of Hg in analyzed samples were 3.7% and 6.2%, respectively. The relative recoveries of blood samples which have been spiked with different levels of Hg are 90-109%. A new deep eutectic solvent consists of two parts: [DMIM]Cl and 1-undecanol in the molar ratio of 1-2. The accuracy of the proposed procedure was also assessed by determining the concentration of the mercury in a standard reference material. All organic mercury (R-Hg) species were converted to Hg and finally, the concentration of R-Hg is simply calculated by mathematically subtracting the concentrations of Hg from the concentration of total mercury (t-Hg). The extraction methodology is simple, rapid, cheap and green since small amounts of non-toxic solvents are necessary.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2018.04.042 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!