Background: Acetabular fracture surgery is directed toward anatomical reduction and stable fixation to allow for the early functional rehabilitation of an injured hip joint. Recent biomechanical investigations have shown the superiority of using an additional screw in the infraacetabular (IA) region, thereby transfixing the separated columns to strengthen the construct by closing the periacetabular fixation frame. However, the inter-individual existence and variance concerning secure IA screw corridors are poorly understood.
Methods: This computer-aided 3-D radiomorphometric study examined 124 CT Digital Imaging and Communications in Medicine (DICOM) datasets of intact human pelves (248 acetabula) to visualize the spatial IA corridors as the sum of all intraosseous screw positions. DICOM files were pre-processed using the Amira® 4.2 visualization software. Final corridor computation was accomplished using a custom-made software algorithm. The volumetric measurement data of each corridor were calculated for further statistical analyses. Correlations between the volumetric values and the biometric data were investigated. Furthermore, the influence of hip dysplasia on the IA corridor configuration was analyzed.
Results: The IA corridors consistently showed a double-cone shape with the isthmus located at the acetabular fovea. In 97% of male and 91% of female acetabula, a corridor for a 3.5-mm screw could be found. The number of IA corridors was significantly lower in females for screw diameters ≥ 4.5 mm. The mean 3.5-mm screw corridor volume was 16 cm in males and 9.2 cm in female pelves. Corridor volumes were significantly positively correlated with body height and weight and with the diameter of Köhler's teardrop on standard AP pelvic X-rays. No correlation was observed between hip dysplasia and the IA corridor extent.
Conclusion: IA corridors are consistently smaller in females. However, 3.5-mm small fragment screws may still be used as the standard implant because sex-specific differences are significant only with screw diameters ≥ 4.5 mm. Congenital hip dysplasia does not affect secure IA screw insertion. The described method allows 3-D shape analyses with highly reliable results. The visualization of secure IA corridors may support the spatial awareness of surgeons. Volumetric data allow the reliable assessment of individual IA corridors using standard AP X-ray views, which aids preoperative planning.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5963032 | PMC |
http://dx.doi.org/10.1186/s13018-018-0833-y | DOI Listing |
Eur Spine J
January 2025
Department of Spine Surgery, The Third Hospital of Hebei Medical University, 139 Ziqiang Road, Shijiazhuang, 050051, China.
Objective: Spinopelvic sagittal balance ensures efficient posture and minimizes energy expenditure by aligning the spine, pelvis, and lower extremities. Deviations can cause clinical issues like back pain and functional limitations. Key radiographic parameters, including pelvic tilt (PT), pelvic incidence (PI), sacral slope (SS), and lumbar lordosis (LL), are essential for evaluating spinal pathologies and planning surgeries.
View Article and Find Full Text PDFJ Arthroplasty
January 2025
Oakland University William Beaumont School of Medicine, Rochester, MI; Department of Orthopedic Surgery, Corewell Health William Beaumont University Hospital, Royal Oak, MI. Electronic address:
Background: Hip instability following total hip arthroplasty (THA) is among the most common indications for revision surgery. The implantation of dual-mobility (DM) systems, designed to improve stability, continues to rise, and thus, characterizing in vivo implant damage modes is paramount.
Methods: Under an implant retrieval protocol, 51 DM THA systems were analyzed.
Arthroplast Today
February 2025
Department of Radiology, Montefiore Medical Center, Bronx, NY.
Background: Periprosthetic hip dislocation after total hip arthroplasty is a devastating postoperative complication. It is often associated with suboptimal orientation of the acetabular component, characterized by the acetabular abduction and anteversion angles obtained from anteroposterior pelvic radiographs. We introduce a novel automated web tool to streamline the subjective and lengthy process of this manual measurement and compare it to manual human measurements.
View Article and Find Full Text PDFThe current study aimed to objectively evaluate the fit of a rectangular, tapered stem to the severely dysplastic hips on the basis of the proximal femoral anatomy and the dimensional properties of the stem. It was hypothesized that the stem size planned with accordance to the diaphyseal canal width alone can accommodate the distal femur successfully with no sizing mismatch. Forty-six patients (53 hips) suffering from secondary osteoarthritis due to hip dysplasia scheduled for total hip arthroplasty (THA) with a subtrochanteric transverse shortening osteotomy were included.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!