Feasibility of simultaneous PET-MR perfusion using a novel cardiac perfusion phantom.

Eur J Hybrid Imaging

2Division of Imaging Sciences, King's College London, Wellcome Trust/EPSRC Medical Engineering Centre, St. Thomas' Hospital, London, UK.

Published: October 2017

Background: PET-MR scanners are beginning to be employed for quantitative myocardial perfusion imaging. In order to examine simultaneous perfusion calculations, this work describes a feasibility study of simultaneous PET-MR of gadolinium-based contrast agent (GBCA) and PET radiotracer in a novel cardiac perfusion phantom.

Results: [F]F and GBCA were injected simultaneously into a cardiac phantom using a range of ground-truth myocardial perfusion rates of 1 to 5 ml/g/min. PET quantification of (ml/g/min) was performed using a single tissue compartment model. MR perfusion was calculated using a model-independent signal deconvolution technique. PET and MR signal traces from the phantom aorta and myocardial sections show true simultaneous PET and MR arterial input functions (AIF) and myocardial uptake respectively at each perfusion rate. Calculation of perfusion parameters showed both and (PET and MR perfusion parameters respectively) to be linearly related with the ground truth perfusion rate ( ), and also linearly related to each other (R = 0.99). The highest difference in perfusion values between and was 16% at 1 ml/g/min, and the mean difference for all other perfusion rates was <3%.

Conclusions: The perfusion phantom allows accurate and reproducible simulation of the myocardial kinetics for simultaneous PET-MR imaging, and may find use in protocol design and development of PET-MR based quantification techniques and direct comparison of quantification of the two modalities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5954708PMC
http://dx.doi.org/10.1186/s41824-017-0008-9DOI Listing

Publication Analysis

Top Keywords

perfusion
13
simultaneous pet-mr
8
novel cardiac
8
cardiac perfusion
8
myocardial perfusion
8
perfusion rates
8
perfusion rate
8
perfusion parameters
8
difference perfusion
8
pet
5

Similar Publications

Objectives: To conduct a meta-analysis of the diagnostic performance of non-contrast magnetic resonance pulmonary angiography (NC-MRPA) and ventilation-perfusion (V/Q) scintigraphy for the detection of acute pulmonary embolism (PE).

Materials And Methods: Systematic searches of electronic databases were conducted from 2000 to 2024. Primary outcomes were per-patient sensitivity and specificity of NC-MRPA and V/Q scintigraphy.

View Article and Find Full Text PDF

Association between intraoperative fluid management and postoperative outcomes in living kidney donors: a retrospective cohort study.

Sci Rep

January 2025

Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81, Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.

Optimal fluid strategy for laparoscopic donor nephrectomy (LDN) remains unclear. LDN has been a domain for liberal fluid management to ensure graft perfusion, but this can result in adverse outcomes due to fluid overload. We compared postoperative outcome of living kidney donors according to the intraoperative fluid management.

View Article and Find Full Text PDF

Finger amputations following complex hand injuries (CHI) pose a significant challenge in hand surgery due to severe tissue trauma and neurovascular damage, necessitating precise arterial repair. While restoring arterial perfusion is critical, it remains unclear whether reconstructing both proper palmar digital arteries is required for optimal outcomes. This study evaluates whether restoring one or both arteries in finger replantation after complex injuries impacts perfusion and overall outcomes.

View Article and Find Full Text PDF

The Role of Imaging in Pulmonary Vascular Disease: The Clinician's Perspective.

Radiol Clin North Am

March 2025

Department of Medicine, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-8558, USA; Department of Pediatrics, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-8558, USA. Electronic address:

Pulmonary vascular diseases, particularly when accompanied by pulmonary hypertension, are complex disorders often requiring multimodal imaging for diagnosis and monitoring. Echocardiography is the primary screening tool for pulmonary hypertension, while cardiac MR imaging (CMR) is used for more detailed characterization and risk stratification in right ventricular failure. Chest computed tomography (CT) is used to detect vascular anomalies and parenchymal lung diseases.

View Article and Find Full Text PDF

Role of Cardiovascular MR Imaging and MR Angiography in Patients with Pulmonary Vascular Disease.

Radiol Clin North Am

March 2025

Radiology Department, Northwestern University Feinberg School of Medicine, Arkes Pavilion, 676 North St Clair Street, Suite 800, Chicago, IL 60611, USA. Electronic address:

Cardiac MR imaging and pulmonary MR angiography (MRA) are important clinical tools for the assessment of pulmonary vascular diseases. There are evolving noncontrast and contrast-enhanced techniques to evaluate pulmonary vasculature. Pulmonary MRA is a feasible imaging alternative to CTA in pulmonary embolism detection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!