A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Adjustments of haptics length for tilted intraocular lens after intrascleral fixation. | LitMetric

Purpose: To report the findings and surgical techniques on two cases of severe tilting of an intraocular lens (IOL) that had been implanted with intrascleral fixation and the tilting was detected by anterior segment optical coherence tomography (AS-OCT).

Observations: Two patients underwent flanged intrascleral fixation of an IOL with the double needle technique. AS-OCT showed that the tilt of IOL was 25.3° in Case 1 and was 38.1° in Case 2, and a second surgery was planned to reduce the IOL tilt. Both edges of the flanged haptics were externalized and shortened by 2-3 mm. Then, the haptics edges were inserted intrasclerally. The tilt of the IOLs was reduced to 7.7° and 5.7°, and the myopia-shifted refraction was reduced from -2.75 diopters (D) and -4.50 D to -0.13 D and -0.50 D of the approximate planned refraction in the two cases.

Conclusions And Importance: An excessive tilt of an intrasclerally fixed IOL can be corrected by shortening the length of the haptics. AS-OCT was useful in not only detecting the tilted IOL but also in monitoring the degree of tilt after adjustment surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5956722PMC
http://dx.doi.org/10.1016/j.ajoc.2018.02.025DOI Listing

Publication Analysis

Top Keywords

intrascleral fixation
12
intraocular lens
8
iol
6
tilt
5
adjustments haptics
4
haptics length
4
length tilted
4
tilted intraocular
4
lens intrascleral
4
fixation purpose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!