AI Article Synopsis

  • This paper analyzes over 50 years of work practices in interventional cardiology, specifically focusing on radiation protection based on a study involving over 400 cardiologists across Europe conducted between 2014 and 2016.
  • The study highlights the importance of using protective measures like ceiling-suspended lead shields and lead glasses to keep radiation exposure below safe limits, especially in haemodynamic procedures.
  • While significant improvements in radiation protection tools have been observed, the paper notes that 7% of haemodynamic procedures still occur without any protective measures.

Article Abstract

This paper investigates over five decades of work practices in interventional cardiology, with an emphasis on radiation protection. The analysis is based on data from more than 400 cardiologists from various European countries recruited for a EURALOC study and collected in the period from 2014 to 2016. Information on the types of procedures performed and their annual mean number, fluoroscopy time, access site choice, x-ray units and radiation protection means used was collected using an occupational questionnaire. Based on the specific European data, changes in each parameter have been analysed over decades, while country-specific data analysis has allowed us to determine the differences in local practices. In particular, based on the collected data, the typical workload of a European cardiologist working in a haemodynamic room and an electrophysiology room was specified for various types of procedures. The results showed that when working in a haemodynamic room, a transparent ceiling-suspended lead shield or lead glasses are necessary in order to remain below the recommended eye lens dose limit of 20 mSv. Moreover, the analysis revealed that new, more complex cardiac procedures such as chronic total occlusion, valvuloplasty and pulmonary vein isolation for atrial fibrillation ablation might contribute substantially to annual doses, although they are relatively rarely performed. The results revealed that considerable progress has been made in the use of radiation protection tools. While their use in electrophysiology procedures is not generic, the situation in haemodynamic procedures is rather encouraging, as ceiling-suspended shields are used in 90% of cases, while the combination of ceiling shield and lead glasses is noted in more than 40% of the procedures. However, we find that still 7% of haemodynamic procedures are performed without any radiation protection tools.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6498/aac64bDOI Listing

Publication Analysis

Top Keywords

radiation protection
20
work practices
8
euraloc study
8
types procedures
8
procedures performed
8
working haemodynamic
8
haemodynamic room
8
shield lead
8
lead glasses
8
protection tools
8

Similar Publications

Inverse dose protraction effects of low-LET radiation: evidence and significance.

Mutat Res Rev Mutat Res

January 2025

Radiation Epidemiology Branch, National Cancer Institute, MD 20892-9778, USA; Faculty of Health, Science and Technology, Oxford Brookes University, Headington Campus, OX3 0BP, UK.

Biological effects of ionizing radiation vary not merely with total dose but also with temporal dose distribution. Sparing dose protraction effects, in which dose protraction reduces effects of radiation have widely been accepted and generally assumed in radiation protection, particularly for stochastic effects (e.g.

View Article and Find Full Text PDF

The three-dimensional radiation field is an important database reflecting the radioactivity distribution in a nuclear facility. It is of great significance to accurately and quickly grasp the radiation dose field distribution to implement radiation protection. Presently, majority of radiation field reconstruction algorithms concentrate on two-dimensional reconstruction and can only measure on a regular grid.

View Article and Find Full Text PDF

Magnetic nanoparticle hyperthermia (MNH) emerges as a promising therapeutic strategy for cancer treatment, leveraging alternating magnetic fields (AMFs) to induce localized heating through magnetic nanoparticles (MNPs). However, the interaction of AMFs with biological tissues leads to non-specific heating caused by eddy currents, triggering thermoregulatory responses and complex thermal gradients throughout the body of the patient. While previous studies have implemented the Atkinson-Brezovich limit to mitigate potential harm, recent research underscores discrepancies between this threshold and clinical outcomes, necessitating a re-evaluation of this safety limit.

View Article and Find Full Text PDF

ThCTi@(6)-C: Th═C Double Bond in a Mixed Actinide-Transition Metal Cluster.

J Am Chem Soc

January 2025

College of Chemistry, Chemical Engineering and Materials Science, and State Key Laboratory of Radiation Medicine and Protection, Soochow University, Suzhou, Jiangsu 215123, P. R. China.

A thorium-carbon double bond that corresponds to the sum of theoretical covalent double bond radii has long been sought after in the study of actinide-ligand multiple bonding as a synthetic target. However, the stabilization of this chemical bond remains a great challenge to date, in part because of a relatively poor energetic matching between 5f-/6d- orbitals of thorium and the 2s-/2p- frontier orbitals of carbon. Herein, we report the successful synthesis of a thorium-carbon double bond in a carbon-bridged actinide-transition metal cluster, i.

View Article and Find Full Text PDF

Cardiac computed tomography angiography (CTA) is a valuable tool in the assessment of congenital and acquired cardiac disease in children. The goal of cardiac CTA is to produce images that are free of motion and provide sufficient characterization of the anatomy in question. Given the complexity of pediatric patient characteristics, including patient size, heart rate, breath-holding capability, and variant anatomy, cardiac CTA technique must be individualized to the patient as well as the indication to answer the clinical question while also minimizing radiation exposure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!