Background: Sufficient tuberosity fixation in proximal humeral fractures treated with shoulder arthroplasty is essential to gain a good clinical outcome. This biomechanical study evaluated the strength of the reattached tuberosities in reverse total shoulder arthroplasty fixed with cables or with sutures in a cerclage-like technique. Considering the mechanical advantages of flexible titanium alloy cables compared with conventional sutures for cerclage-like fixations, we hypothesized that titanium alloy cables would achieve higher fixation strengths of the tuberosities compared with heavy nonabsorbable sutures.

Methods: A 4-part fracture was created on 8-paired proximal human humeri. The tuberosities were reduced anatomically and fixed by 2 heavy nonabsorbable sutures (suture group) or by two 1-mm titanium alloy cables (cable group) in a cerclage-like technique around the neck of the prosthesis. The humeri were placed in a custom-made test setup enabling internal and external rotation. Cyclic loading with a stepwise increasing load magnitude was applied with a material testing machine, starting with 1 Nm and increasing the load by 0.25 Nm after each 100th cycle until failure of the fixation occurred (>15° rotation of the tuberosities). Any motion of the tuberosities was measured with a 3-dimensional ultrasound motion analysis system.

Results: Overall, the cable group reached 1414 ± 372 cycles, and the suture group reached 1257 ± 230 cycles until the fixations failed (P = .313). The suture group showed a significantly higher rotation of the lesser tuberosity relative to the humerus shaft axis after 200, 400, and 600 cycles compared with the cable group (P = .018-.043).

Conclusions: Tuberosities reattached with cable cerclages showed higher fixation strength and therefore less rotation compared with suture cerclages in a 4-part proximal humeral fracture model treated with reverse total shoulder arthroplasty. Whether this higher fixation strength results in higher bony ingrowth rates of the tuberosities and thus leads to a better clinical outcome needs to be investigated in further clinical studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2018.04.003DOI Listing

Publication Analysis

Top Keywords

shoulder arthroplasty
16
proximal humeral
12
titanium alloy
12
alloy cables
12
higher fixation
12
suture group
12
cable group
12
suture cerclages
8
4-part proximal
8
humeral fracture
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!