Background: Recently, novel protocol utilizing Continuous Mononuclear Cell Collection (cMNC) have been introduced for leukapheresis. We compared the efficacy of cMNC with an older protocol - mononuclear cell collection (MNC) for CD34+ cell collection in unrelated donors with negative stem cell collection predictors.

Material And Methods: Retrospective data from a series of 258 consecutive unrelated hematopoietic stem cell donors was included in this single-center study (80 donors collected with cMNC and 178 with MNC). The donors with poor predictors for collection such as low number of circulating CD34+ cells and/or weight disproportion were assigned to the cMNC arm.

Results: The cMNC protocol yielded a higher number of CD34 + cells per donor body weight (7.63 × 10/kg vs 6.82 × 10/kg, p = 0.027). One apheresis was sufficient for collection of target cell number in 89% individuals from both groups despite negative predictors in the cMNC group. In donors with CD34 + cell count <100/μL and a body weight disproportion between donor and recipient one apheresis was sufficient in 83% of donors in cMNC group and in 58% in MNC group (p = 0.0345) with collection efficiency CE2% values of 61% for cMNC and 62% for MNC (p = 0.77).

Conclusion: cMNC protocol is more efficient in donors with low pre-apheresis CD34+ cell count and weight disproportion between donor and recipient. This suggests that the use of cMNC in unrelated donors could possibly further improve the results of HSC collections.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.transci.2018.04.022DOI Listing

Publication Analysis

Top Keywords

cell collection
20
mononuclear cell
12
stem cell
12
continuous mononuclear
8
cell
8
collection
8
collection cmnc
8
cmnc protocol
8
hematopoietic stem
8
donors negative
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!