Indications for MARS-MRI in Patients Treated With Articular Surface Replacement XL Total Hip Arthroplasty.

J Arthroplasty

Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts.

Published: September 2018

Background: The purpose of this study was to identify which patient and clinical factors are predictive of adverse local tissue reaction (ALTR) and to use these factors to create a highly sensitive algorithm for indicating metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) in Articular Surface Replacement (ASR) XL total hip arthroplasty patients. Our secondary aim was to compare our algorithm to existing national guidelines on when to take MARS-MRI in metal-on-metal total hip arthroplasty patients.

Methods: The study consisted of 137 patients treated with unilateral ASR XL implants from a prospective, multicenter study. Patients underwent MARS-MRI regardless of clinical presentation at a mean of 6.2 (range, 3.3-10.4) years from surgery. Univariate and multivariate analyses were conducted to determine which variables were predictive of ALTR. Predictors were used to create an algorithm to indicate MARS-MRI. Finally, we compared our algorithm's ability to detect ALTR to existing guidelines.

Results: We found a visual analog scale pain score ≥2 (odds ratio [OR] = 2.53; P = .023), high blood cobalt (OR = 1.05; P = .023), and male gender (OR = 2.37; P = .034) to be significant predictors of ALTR presence in our cohort. The resultant algorithm achieved 86.4% sensitivity and 60.2% specificity in detecting ALTR within our cohort. Our algorithm had the highest area under the curve and was the only guideline that was significantly predictive of ALTR (P = .014).

Conclusion: Our algorithm including patient-reported pain and sex-specific cutoffs for blood cobalt levels could predict ALTR and indicate MARS-MRI in our cohort of ASR XL metal-on-metal patients with high sensitivity.

Level Of Evidence: Level II, diagnostic study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2018.04.021DOI Listing

Publication Analysis

Top Keywords

total hip
12
hip arthroplasty
12
patients treated
8
articular surface
8
surface replacement
8
predictive altr
8
indicate mars-mri
8
p = 023
8
blood cobalt
8
altr
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!