Residual Force Enhancement Is Attenuated in a Shortening Magnitude-dependent Manner.

Med Sci Sports Exerc

Faculty of Kinesiology, The University of Calgary, Calgary, AB, CANADA.

Published: October 2018

Introduction: The isometric force attained after active stretch is greater than that attained in a purely isometric contraction. This property is referred to as residual force enhancement (RFE). Although RFE is thought to contribute to the enhanced force and power in stretch-shortening cycles (SSCs), it is unclear whether shortening that occurs after active stretch eliminates the RFE induced by active stretch. Therefore, we evaluated the influence of shortening on RFE.

Methods: Skinned rabbit soleus fibers (N = 43) were used for all tests. Residual force enhancement was compared between the stretch-only condition and the SSC condition. In the SSC conditions, shortening magnitudes were either 1% or 12.5% of fiber length. The final muscle length where RFE was evaluated was 3 μm for all trials. In the SSCs with 12.5% shortening, the isometric force before and after the SSC was also compared.

Results: Residual force enhancement was similar between the stretch only (7.9% ± 2.7%) and the SSC with 1% shortening condition (7.1% ± 2.9%) (P = 0.316), whereas RFE was smaller in the SSC with 12.5% shortening (3.5% ± 2.4%) than the stretch-only condition (8.4% ± 2.5%) (P < 0.001). The isometric forces after SSCs (0.437 ± 0.103 mN) were greater than those measured before the SSC (0.422 ± 0.104 mN) (P = 0.016).

Conclusions: Residual force enhancement was preserved when the shortening magnitude was small and was reduced when the shortening magnitude was large. Although RFE was attenuated by the 12.5% shortening, RFE was still observed, suggesting that RFE can contribute to SSCs.

Download full-text PDF

Source
http://dx.doi.org/10.1249/MSS.0000000000001670DOI Listing

Publication Analysis

Top Keywords

residual force
20
force enhancement
20
active stretch
12
125% shortening
12
shortening
10
isometric force
8
rfe
8
stretch-only condition
8
condition ssc
8
shortening magnitude
8

Similar Publications

Robot-assisted Endodontic Retreatment: A Case Report with Clinical Considerations.

J Endod

January 2025

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China; Department of Cariology and Endodontics, School and Hospital of Stomatology, Wuhan University, Wuhan, China. Electronic address:

Introduction: Fiber posts present significant challenges for nonsurgical endodontic retreatment, as improper removal may result in iatrogenic root perforation or even root fracture. Recently, robotic technology has attracted considerable attention in dentistry and active dental robotic (ADR) systems can perform procedures based on preset instructions, minimizing reliance on the dentist's experience. This case report describes the application of an ADR system for fiber post removal through an existing zirconia crown.

View Article and Find Full Text PDF

Objective: Aim: Study the mechanism of interaction between the 'sacroiliac joint - screw' system and determine the optimal parameters of the stabilizing structure, the strength of the system connection through computer modeling, and anatomical-biomechanical experiment.

Patients And Methods: Materials and Methods: The optimal parameters of the stabilizing structure for the sacroiliac joint were calculated using software package MathCAD. To validate the results of the numerical modeling, corresponding investigations of mechanical characteristics and determination of stiffness of the studied systems were conducted by an upgraded testing stand, TIRAtest-2151.

View Article and Find Full Text PDF

Rigid reinforced concrete (RC) frames are generally adopted as stiff elements to make the building structures resistant to seismic forces. However, a method has yet to be fully sought to provide earthquake resistance through optimizing beam and column performance in a rigid frame. Due to its high corrosion resistance, the integration of CFRP offers an opportunity to reduce frequent repairs and increase durability.

View Article and Find Full Text PDF

Interfacial Strain-Driven Large Topological Hall Effects in Supermalloy Thin Films with Noncoplanar Spin Textures.

ACS Appl Mater Interfaces

January 2025

School of Physical Sciences, Indian Association for the Cultivation of Science, 2A & 2B Raja S. C. Mullick Road, Kolkata 700032, India.

Materials exhibiting topological transport properties, such as a large topological Hall resistivity, are crucial for next-generation spintronic devices. Here, we report large topological Hall resistivities in epitaxial supermalloy (NiFeMo) thin films with [100] and [111] orientations grown on single-crystal MgO (100) and AlO (0001) substrates, respectively. While X-ray reciprocal maps confirmed the epitaxial growth of the films, X-ray stress analyses revealed large residual strains in the films, inducing tetragonal distortions of the cubic NiFeMo unit cells.

View Article and Find Full Text PDF

This study investigates the microstructure of dental enamel following demineralization and re-mineralization processes, using DIAGNOdent scores and images obtained via scanning electron microscopy (SEM), atomic force microscopy (AFM), and microhardness (Vickers). The research evaluates the effects of two experimental hydrogels, Anti-Amelogenin isoform X (ABT260, S1) and Anti-Kallikrein L1 (K3014, S2), applied to demineralized enamel surfaces over periods of 14 and 21 days. The study involved 60 extracted teeth, free from cavities or other lesions, divided into four groups: a positive group (+), a negative group (-) and groups S1 and S2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!