To review the use of the contralateral subfrontal approach for the resection of an optic canal meningioma.  Operative video.  A meningioma, located in the inferomedial side of the optic canal ( Fig. 1 ), was found to cause significant visual deterioration. The subfrontal route was preferred to expose the tumor without mobilization of the optic nerve. Drilling of the anterior limb of the chiasmatic sulcus (limbus sphenoidale) provided adequate exposure of the medial aspect of the optic canal. Gross total resection (Simpson II) of the tumor was accomplished, and endoscopic assistance allowed identification and coagulation of an infiltrated dura mater in the chiasmatic sulcus and tuberculum sellae.  The subfrontal approach grants an optimal surgical trajectory to the contralateral chiasmatic sulcus and optic nerve. When the medial side of the optic canal is drilled, tumors extending into the optic canal can be safely resected, under direct visualization of the inferomedial side of the optic nerve. Breach into the sphenoid sinus can occur during drilling of the anterior limb of the chiasmatic sulcus. Endoscopic assistance can provide a better view on blind areas of the surgical field, including the depth of the optic canal ( Fig. 2 ). The link to the video can be found at: https://youtu.be/fS2udUCPH1g .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5954237PMC
http://dx.doi.org/10.1055/s-0037-1620253DOI Listing

Publication Analysis

Top Keywords

optic canal
28
chiasmatic sulcus
16
subfrontal approach
12
endoscopic assistance
12
side optic
12
optic nerve
12
optic
9
resection optic
8
canal meningioma
8
contralateral subfrontal
8

Similar Publications

A rare morphological variant: Bilateral accessory optic canal.

Morphologie

January 2025

Department of Anatomy, Faculty of Medicine-Pharmacy, University of Rouen-Normandy, Rouen, France.

The optic canal (OC) transmits the optic nerve (ON) and ophthalmic artery (OA) from the skull base to the orbit. Its morphological variability is narrow, and most commonly its dimensions are being studied. We observed an unexpected variant during a routine investigation of our osteological collection.

View Article and Find Full Text PDF

The detection of organophosphorus pesticides, particularly chlorpyrifos, in environmental samples is essential due to their widespread use and associated health risks. In this study, we developed a high-sensitivity fluorescent sensing platform utilizing an Isatin-3-allyl-terbium (IS-Tb) complex in solution for the rapid and selective detection of chlorpyrifos in various water samples. The proposed chemical structure of the complex in solution was evaluated using molar ratio method.

View Article and Find Full Text PDF

In recent years, the wine industry has been researching how to improve wine quality along the production value chain. In this scenario, we present here a new tool, MicroVi, a cost-effective chip-sized microscopy solution to detect and count yeast cells in wine samples. We demonstrate that this novel microscopy setup is able to measure the same type of samples as an optical microscopy system, but with smaller size equipment and with automated cell count configuration.

View Article and Find Full Text PDF

Purpose: Trabecular micro-bypass devices (TBDs) such as the iStent series (Glaukos Corporation, Laguna Hills, CA), are effective in reducing intraocular pressure (IOP). However, precise placement of TBDs is crucial in achieving surgical efficacy, as device malpositioning may lead to suboptimal IOP reduction. We demonstrate two novel intra-operative signs to aid confirmation of accurate iStent placement, without reliance on imaging technologies.

View Article and Find Full Text PDF

Introduction: Cataract surgery has been reported to have a reducing effect on intraocular pressure (IOP) in glaucomatous and non-glaucomatous eyes. This effect seems to be more noticeable in eyes with narrow angles (NAs) than in eyes with open angles (OAs). Decrease in IOP may be a result of the increase in anterior chamber angle (ACA) and Schlemm canal (SC) after cataract surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!