A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Nalidixic acid surrogate test for susceptibility to ciprofloxacin in . Revisiting the question. | LitMetric

Nalidixic acid surrogate test for susceptibility to ciprofloxacin in . Revisiting the question.

J Med Microbiol

Departamento de Microbiología-Instituto de Investigación Biosanitaria de Granada, Universidad de Granada, Granada, Spain.

Published: July 2018

We investigated the reliability of nalidixic acid (NA) susceptibility as a marker of ciprofloxacin susceptibility in analysing 302 stool isolates. NC53 of the MicroScan system was used for NA susceptibility tests and the E-test was used for ciprofloxacin susceptibility tests. Among the isolates, 178 (58.9 %) were serogroup B, 74 (24.5 %) were serogroup D, 27 (8.9 %) were serogroup C and 23 (7.6 %) were from other minor serogroups. Globally, susceptibility to NA correctly predicted the susceptibility of to ciprofloxacin, with a sensitivity of 81.5 %, a specificity of 97.6 %, and positive and negative predictive values of 88 and 96 %, respectively. However, there were differences among the serogroups in terms of sensitivity (<0.001) and positive predictive values (=0.013). NA is a reliable marker for serogroup D, but not for serogroups B or C. According to these findings, NA susceptibility measured with the MicroScan system can be used as a marker of ciprofloxacin resistance in some serogroups in our setting.

Download full-text PDF

Source
http://dx.doi.org/10.1099/jmm.0.000755DOI Listing

Publication Analysis

Top Keywords

nalidixic acid
8
susceptibility ciprofloxacin
8
ciprofloxacin susceptibility
8
susceptibility tests
8
susceptibility
7
acid surrogate
4
surrogate test
4
test susceptibility
4
ciprofloxacin
4
ciprofloxacin revisiting
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!