This study assessed the reliability and validity of segment measured accelerations in comparison to front foot contact (FFC) ground reaction force (GRF) during the delivery stride for cricket pace bowlers. Eleven recreational bowlers completed a 30-delivery bowling spell. Trunk- and tibia-mounted inertial measurement units (IMUs) were used to measure accelerations, converted to force, for comparisons to force plate GRF discrete measures. These measures included peak force, impulse and the continuous force-time curve in the vertical and braking (horizontal) planes. Reliability and validity was determined by intra-class correlation coefficients (ICC), coefficient of variation (CV), Bland-Altman plots, paired sample -tests, Pearson's correlation and one-dimensional (1D) statistical parametrical mapping (SPM). All ICC (0.90-0.98) and CV (4.23-7.41%) were acceptable, except for tibia-mounted IMU braking peak force (CV = 12.44%) and impulse (CV = 18.17%) and trunk vertical impulse (CV = 17.93%). Bland-Altman plots revealed wide limits of agreement between discrete IMU force signatures and force plate GRF. The 1D SPM outlined numerous significant ( < 0.01) differences between trunk- and tibia-located IMU-derived measures and force plate GRF traces in vertical and braking (horizontal) planes. The trunk- and tibia-mounted IMUs appeared to not represent the GRF experienced during pace bowling FFC when compared to a gold-standard force plate.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14763141.2018.1465581DOI Listing

Publication Analysis

Top Keywords

force plate
16
plate grf
12
force
9
inertial measurement
8
ground reaction
8
cricket pace
8
pace bowling
8
reliability validity
8
trunk- tibia-mounted
8
peak force
8

Similar Publications

Finite model analysis of different anchorage sites for bone-supported facemask application in unilateral cleft lip and palate.

Am J Orthod Dentofacial Orthop

January 2025

Department of Orthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey. Electronic address:

Introduction: The objective of this study was to evaluate the effects of the miniplate application sites in the maxilla and the applied force vector changes during skeletally supported facemask application in adolescent patients with unilateral cleft lip and palate (UCLP) using finite element model (FEM) analysis.

Methods: A FEM was obtained from a cone-beam computed tomography image of a 12-year-old female patient with UCLP. Miniplates were placed on 3 different sites of the maxilla; 500 g of advancement force was applied bilaterally, parallel (0°), and downward (-30°) to the occlusal plane.

View Article and Find Full Text PDF

Neuromuscular Strategies in Dominant and Non-Dominant Legs in Dancers During Dynamic Balance Tasks.

J Dance Med Sci

January 2025

Frontier Research Institute of Convergence Sports Science, College of Educational Sciences, Yonsei University, Seoul, Korea.

Ballet-based dance training emphasizes the equal development of both legs. However, dancers often perceive differences between their legs during balance or landing. There still needs to be more consensus on the functional difference between dominant (D) and non-dominant legs (ND).

View Article and Find Full Text PDF

Modeling of Electric Field and Dielectrophoretic Force in a Parallel-Plate Cell Separation Device with an Electrode Lid and Analytical Formulation Using Fourier Series.

Sensors (Basel)

December 2024

Department of Applied Physics, National Defense Academy, Hashirimizu 1-10-20, Yokosuka 239-0802, Kanagawa, Japan.

Dielectrophoresis (DEP) cell separation technology is an effective means of separating target cells which are only marginally present in a wide variety of cells. To develop highly efficient cell separation devices, detailed analysis of the nonuniform electric field's intensity distribution within the device is needed, as it affects separation performance. Here we analytically expressed the distributions of the electric field and DEP force in a parallel-plate cell separation DEP device by employing electrostatic analysis through the Fourier series method.

View Article and Find Full Text PDF

The purpose was to create a systematic approach for analyzing data to improve predictive models for fatigue and neuromuscular performance in volleyball, with potential applications in other sports. The study aimed to assess whether average, peak, or peak-to-average ratios of countermovement jump (CMJ) force plate metrics exhibit stronger correlations and determine which metric most effectively predicts performance. Data were obtained from nine division I female volleyball athletes over a season, recording daily jump loads (total jumps, jump counts >38.

View Article and Find Full Text PDF

Objective: Finite element analysis (FEA) of the biomechanical properties of the modified extraoral distractor device used in the mandibular distraction of craniofacial microsomia patients.

Materials And Methods: Finite element analysis (FEA) models of 5 patients under 2 working conditions, the instance when the distractor is activated and when the distractor participates in mastication, were included in the current study. To conduct the FEA, load boundary conditions (35.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!