A side-pump coupler made of fluoride fibers was fabricated and tested. The tested device had a coupling efficiency of 83% and was driven with an incident pump power of up to 83.5 W, demonstrating high-power operation. Stable laser output of 15 W at a wavelength of around 2.8 μm was achieved over 1 h when using an erbium-doped double-clad fiber as the active medium. To the best of our knowledge, this is the first time a fluoride-glass-fiber-based side-pump coupler has been developed. A test with two devices demonstrated further power scalability.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.43.002340DOI Listing

Publication Analysis

Top Keywords

side-pump coupler
12
fluoride-fiber-based side-pump
4
coupler high-power
4
high-power fiber
4
fiber lasers
4
lasers 28  μm
4
28  μm side-pump
4
coupler fluoride
4
fluoride fibers
4
fibers fabricated
4

Similar Publications

Fiber side-pump couplers can enhance the output power of fiber laser due to their dependable and efficient operation and impressive power handling capability. We developed a tellurite fiber side-pump coupler by twisting and fusing a tapered pump fiber onto a target fiber. The effect of twisting parameters on coupling efficiency was comprehensively investigated through theoretical simulations and experiments.

View Article and Find Full Text PDF

We investigate the power scaling and thermal management of multi-point side-pumped 2.825 µm heavily-erbium-doped fluoride fiber lasers by numerical simulation. The 4-point (or 6-point) erbium-doped fluoride fiber laser with polished erbium-doped fluoride fiber-based side-pump couplers delivers an output laser power of over 100 W at each launched 981 nm pump power of 100 W (or 75 W).

View Article and Find Full Text PDF

In this study, (1 + 1) × 1 side-pump couplers made of tellurite fibers were fabricated and investigated. The whole optical design of the coupler was established on the basis of ray tracing models and validated by experimental results. By optimizing the preparation conditions and structural parameters, the tested component achieved a coupling efficiency of 67.

View Article and Find Full Text PDF

A side-pump coupler made of fluoride fibers was fabricated and tested. The tested device had a coupling efficiency of 83% and was driven with an incident pump power of up to 83.5 W, demonstrating high-power operation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!