Objectives: Predictors of residual leak following percutaneous LAA closure were evaluated.
Background: Left atrial appendage (LAA) closure aims to exclude this structure from the circulation, typically using a circular occluder. A noncircular orifice is frequently encountered however, and fibrous remodeling of the LAA in atrial fibrillation may restrict orifice deformation. Noncircularity may thus be implicated in the occurrence of residual leak despite an appropriately oversized device.
Methods: Pre-procedural multislice computerized tomography was used to quantify LAA orifice eccentricity and irregularity. Univariate predictors of residual leak were identified with respect to the orifice, device, and relevant clinical variables, with the nature of any correlations then further evaluated.
Results: Eccentricity and irregularity indexes of the orifice in 31 individuals were correlated with residual leak even where the device was appropriately oversized. An eccentricity index of 0.15 predicted a residual leak with 85% sensitivity and 59% specificity. An irregularity index of 0.05 predicted a significant residual leak ≥3 mm with 100% sensitivity and 86% specificity. Orifice size, device size, degree of device oversize, left atrial volume, and pulmonary artery pressure were not predictors of residual leak.
Conclusions: Eccentricity and irregularity of the LAA orifice are implicated in residual leak after percutaneous closure even where there is appropriate device over-size. Irregularity index in particular is a novel predictor of residual leak, supporting a closer consideration of orifice morphology before closure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacep.2015.08.006 | DOI Listing |
Int J Biol Macromol
December 2024
School of Chemistry and Life Sciences, Suzhou University of Science and Technology, Suzhou 215009, China. Electronic address:
The cascade of sugar isomerases is one of the most practical methods for producing rare sugars, and enzyme immobilization endows it with high economic efficiency, operational convenience and reusability. However, the most employed cross-linker glutaraldehyde (GA) has the disadvantages of enzyme deactivation and limitation of substrate binding. Herein, three compounds, glyoxal, GA, and 2,5-furandicarboxaldehyde (DFF) were evaluated within a previously developed cascade comprising ribose-5-phosphate isomerase and D-tagatose-3-epimerase to prepare D-ribulose form D-xylose.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
December 2024
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Background: Research on the impact of angiographically detected residual trabeculation after left atrial appendage closure (LAAC) is limited.
Objectives: To investigate the incidence, characteristics, and clinical implications of angiographically detected residual trabeculation after LAAC using the WATCHMAN device.
Methods: We analyzed 1350 consecutive patients with atrial fibrillation undergoing LAAC using the WATCHMAN device from the OCEAN-LAAC registry, which is a prospective ongoing, multicenter Japanese registry.
Rev Cardiovasc Med
November 2024
The First Clinical Medical College of Lanzhou University, 730000 Lanzhou, Gansu, China.
Cureus
October 2024
General Surgery, Rajendra Institute of Medical Sciences, Ranchi, IND.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!