A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrochemical detection of microcystin-LR based on its deleterious effect on DNA. | LitMetric

Electrochemical detection of microcystin-LR based on its deleterious effect on DNA.

Talanta

Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, PR China; Department of Chemistry, University of British Columbia, Vancouver, BC, Canada V6T 1Z1. Electronic address:

Published: August 2018

This work reveals the deleterious effect of microcystin-LR (MC-LR) on the conformation of DNA and develops an electrochemical biosensor for detection of MC-LR. The biosensor is prepared by physically immobilizing calf thymus DNA (ctDNA) on gold electrode. In the presence of MC-LR, the conformation change of immobilized ctDNA decreases the electron transfer impedance, thus enhances the amperometric response. The proposed method shows a linear range of 4-512 ng/L and a detection limit of 1.4 ng/L, which is 700-fold lower than the guideline level suggested by the World Health Organization. The detection results are in good agreement with those from the conventional HPLC method. This biosensor possesses good stability against other components in natural water sample, and has been used for detection of MC-LR in local water bodies, indicating its application promise.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2018.03.051DOI Listing

Publication Analysis

Top Keywords

mc-lr conformation
8
detection mc-lr
8
electrochemical detection
4
detection microcystin-lr
4
microcystin-lr based
4
based deleterious
4
deleterious dna
4
dna work
4
work reveals
4
reveals deleterious
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!