Introduction: Central vascular cannulation in children is a highly complex technique and poses many difficulties. Vascular ultrasound can make this procedure easier.
Objective: To describe the characteristics of ultrasound-guided vascular cannulation in critically-ill pediatric patients.
Population And Methods: Outcome measures prospectively recorded were vessels most frequently cannulated, their localization, the measurement of their diameter/depth, the success rate and complications developed, among others.
Results: One hundred and twenty four vascular punctures were performed in 86 pediatric patients. Vascular accesses were the femoral vein (39.7%), followed by the femoral artery (27.2%) and the internal jugular vein (14.7%). Femoral vessels were localized at a depth of 0.75 ± 0.25 mm, with a mean diameter of 0.31 ± 0.16 mm. The depth of jugular vein vessels was smaller (0.64 ± 0.24 mm) and their overall diameter, larger (0.44 ± 0.19 mm). The mean number of attempts in ultrasound-guided cannulations was 2.2 ± 1.3. The success rate was 79% and was associated to a larger vessel diameter (0.39 ± 0.20 mm vs. 0.28 ± 0.13 mm, p= 0.01) and a lower number of attempts (1.90 ± 1.16 vs. 3.45 ± 1.77, p= 0.001). Complications were accidental puncture of another vessel (5.3%) and hematoma formation during puncture (2.3%).
Conclusions: In the pediatric patients studied, ultrasound-guided vascular cannulation allowed vessel visualization and measurement of their depth and diameter; the success rate was high and it was associated to a low complication rate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5546/aap.2018.eng.204 | DOI Listing |
Pulmonary artery (PA) flow analysis is crucial for understanding the progression of pulmonary hypertension (PH). We hypothesized that PA flow characteristics vary according to PH etiology. In this study, we used 4D flow cardiovascular magnetic resonance imaging (CMR) to compare PA flow velocity and wall shear stress (WSS) between patients with pulmonary arterial hypertension (PAH) and those with heart failure with preserved ejection fraction and pulmonary hypertension (PH-HFpEF).
View Article and Find Full Text PDFCardiovasc Ultrasound
January 2025
Cardiology Department, Hospital de Santa Marta, Unidade Local de Saúde São José, Centro Clínico Académico de Lisboa, Rua de Santa Marta N.º 50, Lisbon, 1169-024, Portugal.
Background: Right ventricular myocardial work (RVMW) assessed by transthoracic echocardiography allows to study the right ventricular (RV) function using RV pressure-strain loops. The assessment of these novel indexes of RVMW has not yet been exten sively studied, namely in pre-capillary pulmonary hypertension (PH) population.
Objectives: to evaluate the relationship between RVMW and invasive indices of right heart catheterization (RHC) in a cohort of patients with group I and group IV PH and to compare with a control group without PH.
Sci Rep
January 2025
Department of Cardiovascular, The Second Affiliated Hospital of Chongqing Medical University, No. 74, Linjiang Road, Yuzhong District, Chongqing, 400010, China.
In order to provide some references for vein approach selection in adrenal vein sampling (AVS), this retrospective study analyzed 325 cases of primary aldosteronism (PA) patients who underwent AVS via the upper extremity vein approach, comparing the differences in complications and visual analogue scale (VAS) scores through median cubital vein (MCV), basilic vein (BV), and cephalic vein (CV). The results indicated no significant difference in the incidence of venous spasm (right MCV vs. right BV vs.
View Article and Find Full Text PDFEur J Vasc Endovasc Surg
December 2024
Division of Vascular Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Department of Clinical Science and Education, Karolinska Institutet, Södersjukhuset, Stockholm, Sweden.
Objective: Emergent complex abdominal aortic diseases are challenging to treat. During in situ laser fenestration (ISLF), aortic branches are covered and flow is restored with in situ fenestration of the stent graft, with promising midterm results. This study aimed to expand on the limited body of knowledge of midterm outcomes of ISLF in renovisceral aortic pathology in a multicentre setting.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Korea.
Background: Monitoring core temperature is important for patients under anesthesia. Esophageal and pulmonary artery blood temperatures can be used for measuring core temperature during general anesthesia. However, these methods pose challenges, especially when the placement of an esophageal thermometer and pulmonary artery catheter (PAC) is either impractical or not the preferred approach.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!