Challenges in paper-based fluorogenic optical sensing with smartphones.

Nano Converg

Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721 USA.

Published: May 2018

Application of optically superior, tunable fluorescent nanotechnologies have long been demonstrated throughout many chemical and biological sensing applications. Combined with microfluidics technologies, i.e. on lab-on-a-chip platforms, such fluorescent nanotechnologies have often enabled extreme sensitivity, sometimes down to single molecule level. Within recent years there has been a peak interest in translating fluorescent nanotechnology onto paper-based platforms for chemical and biological sensing, as a simple, low-cost, disposable alternative to conventional silicone-based microfluidic substrates. On the other hand, smartphone integration as an optical detection system as well as user interface and data processing component has been widely attempted, serving as a gateway to on-board quantitative processing, enhanced mobility, and interconnectivity with informational networks. Smartphone sensing can be integrated to these paper-based fluorogenic assays towards demonstrating extreme sensitivity as well as ease-of-use and low-cost. However, with these emerging technologies there are always technical limitations that must be addressed; for example, paper's autofluorescence that perturbs fluorogenic sensing; smartphone flash's limitations in fluorescent excitation; smartphone camera's limitations in detecting narrow-band fluorescent emission, etc. In this review, physical optical setups, digital enhancement algorithms, and various fluorescent measurement techniques are discussed and pinpointed as areas of opportunities to further improve paper-based fluorogenic optical sensing with smartphones.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937860PMC
http://dx.doi.org/10.1186/s40580-018-0146-1DOI Listing

Publication Analysis

Top Keywords

paper-based fluorogenic
12
fluorogenic optical
8
optical sensing
8
sensing smartphones
8
fluorescent nanotechnologies
8
chemical biological
8
biological sensing
8
extreme sensitivity
8
sensing
6
fluorescent
6

Similar Publications

MnO-triggered wavelength-changeable and rapid-response fluorescence sensor for paper-based on-site sensing of tyrosinase activity in potato.

Talanta

January 2025

Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), School of Flexible Electronics (Future Technologies), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, China. Electronic address:

Rapid-response in situ fluorogenic reactions in aqueous solution are important for designing sensitive and stable sensing platforms. Herein, a wavelength-changeable and rapid-response (within 5 s) fluorescence sensing platform for monitoring tyrosinase (TYR) activity is constructed. The developed assay is based on TYR catalyzing the hydroxylation of mono-phenol to o-diphenol and MnO-triggered fluorogenic between dopamine (DA) and phenol derivatives in aqueous solution.

View Article and Find Full Text PDF

Among the various essential trace elements for living organisms, the copper (Cu) ions are the most important. However, Cu ions are vital for the human body and are associated with necessary physiological processes; insufficient or excessiveness has many hazardous effects on our bodies. In the present contribution, strategically, we have introduced a julolidine-coupled azine-based, 9,9'-((1E,1'E)-hydrazine-1,2-diylidene bis(methanylylidene)) bis(1,2,3,5,6,7-hexahydropyrido [3,2,1-ij] quinolin-8-ol) (HDBQ) reversible chromo-fluorogenic probe for specific detection of Cu ions.

View Article and Find Full Text PDF

Fabrication of a paper-based facile and low-cost microfluidic device and digital imaging technique for point-of-need monitoring of hypochlorite.

Analyst

August 2023

Analytical & Environmental Science Division and Centralized Instrument Facility, CSIR-CSMCRI, G. B. Marg, Bhavnagar, India.

Lab-on-a-paper-based devices are promising alternatives to the existing arduous techniques for point-of-need monitoring. The present work reports an instant and facile method to produce a microfluidic paper-based analytical device (μPAD). The fabricated μPAD has been used to detect hypochlorite (OCl) by incorporating newly synthesized chromo-fluorogenic ratiometric probes 1 and 2 into the sample reception zone.

View Article and Find Full Text PDF

Paper-Based Analytical Devices for Colorimetric and Luminescent Detection of Mercury in Waters: An Overview.

Sensors (Basel)

November 2021

Centro de Investigación Mariña, Departamento de Química Analítica e Alimentaria, Campus de Vigo, Universidade de Vigo, Grupo QA2, Edificio CC Experimentais, As Lagoas, Marcosende, 36310 Vigo, Spain.

Lab-on-paper technologies, also known as paper-based analytical devices (PADs), have received increasing attention in the last years, and nowadays, their use has spread to virtually every application area, i.e., medical diagnostic, food safety, environmental monitoring, etc.

View Article and Find Full Text PDF

Reaction-based chemical switches are attracting great interest due to their high selectivity, and their use has become a powerful technique for developing fluorogenic probes. Herein, a benzorhodol-derivative-attached N-oxide probe (DEBNox) has been designed as a new fluorogenic probe for the detection of the biologically toxic species bilirubin based on a deoxygenation switching mechanism. Upon reaction with added Fe, bilirubin produces Fe ions , which in turn promote a deoxygenation reaction with DEBNox to generate the corresponding high-red-fluorescence (: ∼623 nm) benzorhodol derivative (DEB).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!