A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Inspection of endoscope instrument channels after reprocessing using a prototype borescope. | LitMetric

Inspection of endoscope instrument channels after reprocessing using a prototype borescope.

Gastrointest Endosc

Vatche and Tamar Manoukian Division of Digestive Diseases, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California, USA.

Published: October 2018

Background And Aims: Visual inspection of the instrument channel has been proposed as a quality assurance step during endoscope reprocessing. However, the nature and severity of findings in a broad array of endoscopes (gastroscopes, colonoscopes, duodenoscopes, and echoendoscopes) after systemic implementation of an inspection protocol remain unknown. In addition, a study using borescope inspection in upper endoscopes and colonoscopes raised concerns about persistent simethicone residue despite full reprocessing.

Methods: A pilot inspection study using a prototype borescope (SteriCam Inspection Scope; SteriView Inc, San Rafael, Calif) was performed on routinely used endoscopes after high-level disinfection, manual forced-air dry of the instrument channel, and overnight vertical storage. Video recordings 1.5 to 2 minutes in duration were reviewed for visible moisture, debris, discoloration, scratches, channel shredding (scratches that result in strips or filaments of the channel lining protruding into the lumen), and visible evidence of biofilm or simethicone residue.

Results: A total of 97 inspections of 59 endoscopes were reviewed. The most common finding was scratches, seen in 51 devices (86%). Channel shredding was found in 35 devices (59%). Intrachannel debris was identified in 22 (23%) of the 97 inspections. No moisture was seen (0%) in the 74 inspections performed after forced-air dry and overnight vertical storage compared with moisture in 5 of 18 inspections (28%) performed after storage alone. No visual evidence of biofilm or simethicone residue was discovered despite its frequent use in our unit.

Conclusion: Internal defects of the instrument channel appear to occur frequently. Manual forced-air drying of the channel appears to be highly effective in eliminating moisture compared with overnight hang drying alone. Video inspection of the endoscope channel may be useful to audit reprocessing performance and to identify damaged endoscopes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2018.04.2366DOI Listing

Publication Analysis

Top Keywords

instrument channel
12
inspection endoscope
8
prototype borescope
8
channel
8
simethicone residue
8
manual forced-air
8
forced-air dry
8
overnight vertical
8
vertical storage
8
channel shredding
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!