A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative Analysis of Nutrient Elements in Soil Using Single and Double-Pulse Laser-Induced Breakdown Spectroscopy. | LitMetric

Rapid detection of soil nutrient elements is beneficial to the evaluation of crop yield, and it's of great significance in agricultural production. The aim of this work was to compare the detection ability of single-pulse (SP) and collinear double-pulse (DP) laser-induced breakdown spectroscopy (LIBS) for soil nutrient elements and obtain an accurate and reliable method for rapid detection of soil nutrient elements. 63 soil samples were collected for SP and collinear DP signal acquisition, respectively. Macro-nutrients (K, Ca, Mg) and micro-nutrients (Fe, Mn, Na) were analyzed. Three main aspects of all elements were investigated, including spectral intensity, signal stability, and detection sensitivity. Signal-to-noise ratio (SNR) and relative standard deviation (RSD) of elemental spectra were applied to evaluate the stability of SP and collinear DP signals. In terms of detection sensitivity, the performance of chemometrics models (univariate and multivariate analysis models) and the limit of detection (LOD) of elements were analyzed, and the results indicated that the DP-LIBS technique coupled with PLSR could be an accurate and reliable method in the quantitative determination of soil nutrient elements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5982673PMC
http://dx.doi.org/10.3390/s18051526DOI Listing

Publication Analysis

Top Keywords

nutrient elements
20
soil nutrient
16
elements soil
8
double-pulse laser-induced
8
laser-induced breakdown
8
breakdown spectroscopy
8
rapid detection
8
detection soil
8
accurate reliable
8
reliable method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!