Piezoelectric ceramic resonant pressure sensors have shown potential as sensing elements for harsh environments, such as elevated temperatures. For operating temperatures exceeding ~250 °C, conventional and widely used Pb(Zr,Ti)O₃ (PZT) piezoelectrics should be replaced. Here, a ceramic pressure sensor from low-temperature co-fired ceramics (LTCC) was constructed by integrating a piezoelectric actuator made from bismuth ferrite (BiFeO₃) on a diaphragm. This ferroelectric material was selected because of its high Curie temperature (T = 825 °C) and as a lead-free piezoelectric extensively investigated for high-temperature applications. In order to construct a sensor with suitable pressure sensitivity, numerical simulations were used to define the optimum construction dimensions. The functionality of the pressure sensor was tested up to 201 °C. The measurements confirmed a pressure sensitivity, i.e., resonance frequency shift of the sensor per unit of pressure, of 8.7 Hz/kPa up to 171 °C. It was suggested that the main reason for the hindered operation at the elevated temperatures could lie in the thermo-mechanical properties of the diaphragm and the adhesive bonding at the actuator-diaphragm interconnection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5982633PMC
http://dx.doi.org/10.3390/s18051423DOI Listing

Publication Analysis

Top Keywords

pressure sensor
12
elevated temperatures
12
ceramic resonant
8
resonant pressure
8
operation elevated
8
pressure sensitivity
8
pressure
7
sensor
5
construction functionality
4
functionality ceramic
4

Similar Publications

Background: Intrabdominal pressure (IAP) is an important parameter. Elevated IAP can reduce visceral perfusion, lead to intraabdominal hypertension, and result in life-threatening abdominal compartment syndrome. While ingestible capsular devices have been used for various abdominal diagnoses, their application in continuous IAP monitoring remains unproven.

View Article and Find Full Text PDF

Measurement and Assessment of Head-to-Helmet Contact Forces.

Ann Biomed Eng

January 2025

Department of Mechanical and Industrial Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA.

Purpose: To evaluate the population variation in head-to-helmet contact forces in helmet users.

Methods: Four different size Kevlar composite helmets were instrumented with contact pressure sensors and chinstrap tension meters. A total number of 89 volunteers (25 female and 64 male volunteers) participated in the study.

View Article and Find Full Text PDF

The importance of continuous and reliable pulse wave monitoring is constantly being increased in health signal monitoring and disease diagnoses. Flexible pressure sensors with high sensitivity, low hysteresis and fast response time are an effective means for monitoring pulses. Herein, a special wave-shaped layered porous structure of carbonized wood cellulose sponge (CWCS) was constructed based on natural wood (NW).

View Article and Find Full Text PDF

Carbon nanomaterials, particularly carbon nanotubes (CNTs), are widely used as reinforcing fillers in rubber composites for advanced mechanical and electrical applications. However, the influence of rubber functionality and its interactions with CNTs remains underexplored. This study investigates electroactive elastomeric composites fabricated with CNTs in two common diene rubbers: natural rubber (NR) and acrylonitrile-butadiene rubber (NBR), each with distinct functionalities.

View Article and Find Full Text PDF

Mid-infrared spectral analysis has long been recognized as the most accurate noninvasive blood glucose measurement method, yet no practical compact mid-infrared blood glucose sensor has ever passed the accuracy benchmark set by the USA Food and Drug Administration (FDA): to substitute for the finger-pricking glucometers in the market, a new sensor must first show that 95% of their glucose measurements have errors below 15% of these glucometers. Although recent innovative exploitations of the well-established Fourier-transform infrared (FTIR) spectroscopy have reached such FDA accuracy benchmarks, an FTIR spectrometer is too bulky. The advancements of quantum cascade lasers (QCLs) can lead to FTIR spectrometers of reduced size, but compact QCL-based noninvasive blood glucose sensors are not yet available.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!