Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
It remains an issue to directly quantify trace biologically important carboxyl compounds in body fluids. Herein we propose an innovative method to determine α-lipoic acid, 2-(β-carboxyethyl)-6-hydroxy-2,7,8-trimethylchroman, prostaglandin E, cholic acid, and chenodeoxycholic acid in saliva. The method consists of two successive steps: fast and direct labeling of the target analytes with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide followed by ultrahigh-performance liquid chromatography-tandem mass spectrometry analysis. The method exhibited a wide linear range from 2.5 to 2500 pg/mL, with linear coefficients greater than 0.9963 and limits of detection and quantification as low as 0.10 and 0.33 pg/mL, respectively. The method precision was evaluated, with relative standard deviations ranging from 2.12% to 10.63% for intraday assays and from 2.98% to 12.88% for interday assays. The recoveries were measured by our spiking saliva samples with standards at three different levels, and ranged from 72.5% to 98.0%. Real applicability was validated by direct quantification of trace target analytes in human saliva, with simple pretreatment, use of a small sample volume, and a short analysis time. Graphical abstract Sequential steps to extract, label, and determine the ultratrace carboxylic acids in saliva. CDCA chenodeoxycholic acid, γ-CEHC 2-(β-carboxyethyl)-6-hydroxy-2,7,8-trimethylchroman, α-LA α-lipoic acid, PGE prostaglandin E, UHPLC-MS/MS ultrahigh-performance liquid chromatography-tandem mass spectrometry.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00216-018-1078-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!