Guiding Device for the Patellar Cut in Total Knee Arthroplasty: Design and Validation.

Bioengineering (Basel)

Biomedical Engineering and McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB T2N 1N4, Canada.

Published: May 2018

An incorrect cut of the patella (kneecap) during total knee arthroplasty, affects the thickness in different quadrants of the patella, leading to pain and poor function. Because of the disadvantages of existing devices, many surgeons choose to perform the cut freehand. Given this mistrust of existing devices, a quick, but accurate, method is needed that guides the cut, without constraining the surgeon. A novel device is described that allows the surgeon to mark a line at the desired cutting plane parallel to the front (anterior) surface using a cautery tool, remove the device, and then align the saw guide, reamer, or freehand saw with the marked line to cut the patella. The device was tested on 36 artificial patellae, custom-molded from two shapes considered easier and harder to resect accurately, and eight paired cadaveric specimens, each in comparison to the conventional saw guide technique. The mediolateral angle, superoinferior angle, difference from intended thickness, and time were comparable or better for the new device. Addressing the remaining outliers should be possible through additional design changes. Use of this guidance device has the potential to improve patellar resection accuracy, as well as provide training to residents and a double-check and feedback tool for expert surgeons.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6027333PMC
http://dx.doi.org/10.3390/bioengineering5020038DOI Listing

Publication Analysis

Top Keywords

total knee
8
knee arthroplasty
8
cut patella
8
existing devices
8
cut
5
device
5
guiding device
4
device patellar
4
patellar cut
4
cut total
4

Similar Publications

Published in 2003 by the Institute of Medicine, Unequal Treatment: Confronting Racial and Ethnic Disparities in Health Care placed an unprecedented spotlight on disparities in the U.S. health-care system.

View Article and Find Full Text PDF

Purpose: Knee pain is a characteristic symptom of early-stage knee osteoarthritis. Recently, the association between knee symptoms and infrapatellar fat pad (IFP) degeneration has garnered attention. This study aimed to clarify the association between ultrasound-derived size and echo intensity (EI) in the IFP and knee symptoms.

View Article and Find Full Text PDF

Background: Complete blood cell count-based ratios (CBRs), including the neutrophil-lymphocyte ratio (NLR) and monocyte-lymphocyte ratio (MLR), are inflammatory markers associated with postoperative morbidity. Given the link between the surgical stress response and complications after total joint arthroplasty (TJA), this study aimed to evaluate whether higher preoperative CBR values predict greater postoperative benefits associated with dexamethasone utilization.

Methods: The Premier Healthcare Database was queried for adult patients who underwent primary, elective total hip or knee arthroplasty (THA or TKA).

View Article and Find Full Text PDF

Background: Early knee effusion is a common phenomenon after total knee arthroplasty (TKA), with potential clinical implications. Unlike traditional alloy knee prostheses, the polyetheretherketone (PEEK) knee system has radiographic transparency on magnetic resonance (MR) scans, which allows analysis of prosthetic knee effusion. We aimed to identify the distribution and volume of knee effusion after TKA with the PEEK prosthesis with use of MR imaging and to analyze whether dynamic changes in effusion were correlated with serum inflammatory marker changes and knee function recovery.

View Article and Find Full Text PDF

Background: Antiseptic solutions are commonly utilized during total joint arthroplasty (TJA) to prevent and treat periprosthetic joint infection (PJI). The purpose of this study was to investigate which antiseptic solution is most effective against methicillin-sensitive Staphylococcus aureus (MSSA) and Escherichia coli biofilms established in vitro on orthopaedic surfaces commonly utilized in total knee arthroplasty: cobalt-chromium (CC), oxidized zirconium (OxZr), and polymethylmethacrylate (PMMA).

Methods: MSSA and E.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!