A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Eliciting Higher Maximal and Submaximal Cardiorespiratory Responses During a New Taekwondo-Specific Aerobic Test. | LitMetric

Purpose: To propose and validate new taekwondo-specific cardiopulmonary exercise tests.

Methods: Twelve male national-level taekwondo athletes (age 20 [2] y, body mass 67.5 [5.7] kg, height 175 [8] cm, and training experience 7 [3] y) performed 3 separate exercise tests in a randomized counterbalanced order: (1) a treadmill running cardiopulmonary exercise test (CPET) and (2) continuous and (3) interval taekwondo-specific cardiopulmonary exercise tests (cTKDet and iTKDet, respectively). The CPET was administered using an individualized ramp protocol. Taekwondo tests comprised sequences of turning kicks performed on a stationary target. The impacts were recorded via an electronic scoring sensor used in official competition. Stages on the cTKDet and iTKDet lasted 1 min and progressively reduced the kick interval duration. These were guided by a sound signal, starting with 4.6 s between kicks and reducing by 0.4 s every minute until the test ended. Oxygen uptake (V˙O2), heart rate (HR), capillary blood lactate, and ratings of perceived exertion were measured.

Results: Modest differences were identified in V˙O2max between the tests (F2,22 = 3.54; P = .046; effect size [ES] = 0.16). Maximal HR (HRmax) was higher during both taekwondo tests (F2,22 = 14.3; P = .001; ES = 1.14) compared with CPET. Specific tests also yielded higher responses in the first ventilatory threshold V˙O2 (F2,22 = 6.5; P = .04; ES = 0.27) and HR (F2,22 = 12.3; P < .001; ES = 1.06), and HR at the second ventilatory threshold (F2,22 = 5.7; P = .02; ES = 0.72).

Conclusions: Taekwondo-specific cardiopulmonary tests enhance the validity of some cardiopulmonary responses and might therefore be considered to optimize routine diagnostic testing and training prescription for this athletic group.

Download full-text PDF

Source
http://dx.doi.org/10.1123/ijspp.2017-0846DOI Listing

Publication Analysis

Top Keywords

taekwondo-specific cardiopulmonary
12
cardiopulmonary exercise
12
exercise tests
8
ctkdet itkdet
8
taekwondo tests
8
tests f222
8
ventilatory threshold
8
tests
7
cardiopulmonary
5
f222
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!