Purpose: To obtain multicontrast images including fat-suppressed contrast image, a novel multicontrast imaging method using an SSFP sequence with alternating RF flip angles is proposed.

Methods: The proposed method uses the balanced SSFP sequence with 2 flip angles. In general, the conventional balanced SSFP sequence has its own unique contrast, which combines both FID signal and echo signal under a steady-state condition. By using alternating RF flip angles and RF phase cycling, various image contrasts weighted by proton density, T , and T can be obtained. The proposed method offers multicontrast images with fat suppression by using the combination of 2 images obtained just after alternating RF pulses, respectively.

Results: As demonstrated by simulations, phantom and in vivo experiments, the proposed method provides multicontrast knee images including fat-suppressed contrast images.

Conclusion: The proposed method can be a useful tool for clinical diagnosis, such as the cartilage segmentation and the fast screening of lesions.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.27342DOI Listing

Publication Analysis

Top Keywords

flip angles
16
proposed method
16
alternating flip
12
ssfp sequence
12
multicontrast imaging
8
imaging method
8
multicontrast images
8
images including
8
including fat-suppressed
8
fat-suppressed contrast
8

Similar Publications

Wave-CAIPI Multiparameter MR Imaging in Neurology.

NMR Biomed

March 2025

Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.

In clinical practice, particularly in neurology assessments, imaging multiparametric MR images with a single-sequence scan is often limited by either insufficient imaging contrast or the constraints of accelerated imaging techniques. A novel single scan 3D imaging method, incorporating Wave-CAIPI and MULTIPLEX technologies and named WAMP, has been developed for rapid and comprehensive parametric imaging in clinical diagnostic applications. Featuring a hybrid design that includes wave encoding, the CAIPIRINHA sampling pattern, dual time of repetition (TR), dual flip angle (FA), multiecho, and optional flow modulation, the WAMP method captures information on RF B1t fields, proton density (PD), T1, susceptibility, and blood flow.

View Article and Find Full Text PDF

Purpose: The depth within the body, small diameter, long length, and varying tissue surrounding the spinal cord impose specific considerations when designing radiofrequency coils. The optimal coil configuration for 7 T cervical spinal cord MRI is unknown and, currently, there are very few coil options. The purpose of this work was (1) to establish a quality control protocol for evaluating 7 T cervical spinal cord coils and (2) to use that protocol to evaluate the performance of 4 different coil designs.

View Article and Find Full Text PDF

: Legg-Calvé-Perthes disease (LCPD) presents challenges in treatment due to its varied course and unclear etiology. This study aimed to evaluate the efficacy of combining proximal femoral varus osteotomy (PFVO) with a modified trochanteric flip osteotomy to address biomechanical consequences and improve hip abductor muscle strength. : We present a modified approach combining PFVO with a trochanteric flip osteotomy.

View Article and Find Full Text PDF

Gadopiclenol Enables Reduced Gadolinium Dose While Maintaining Quality of Pulmonary Arterial Enhancement for Pulmonary MRA: An Opportunity for Improved Safety and Sustainability.

Invest Radiol

January 2025

From the Departments of Radiology (J.F.H., S.Y.C., J.-P.G., J.S., P.N., S.B.R., T.M.G.), Biomedical Engineering (S.B.R., T.M.G.), Medical Physics (S.Y.C., S.B.R., T.M.G.), Medicine (S.B.R.), and Emergency Medicine (S.B.R.), University of Wisconsin-Madison, WI; and Department of Diagnostic and Interventional Radiology (J.F.H., J.-P.G.), University Hospital Würzburg, Würzburg, Germany.

Rationale And Objectives: Pulmonary magnetic resonance angiography (MRA) is an imaging method with proven utility for the exclusion of pulmonary embolism and avoids the need for ionizing radiation and iodinated contrast agents. High-relaxivity gadolinium-based contrast agents (GBCAs), such as gadopiclenol, can be used to reduce the required gadolinium dose for pulmonary MRA. The aim of this study was to compare the contrast enhancement performance of gadopiclenol with an established gadobenate dimeglumine-enhanced pulmonary MRA protocol.

View Article and Find Full Text PDF

Purpose: The single reference variable flip angle sequence with a multi-echo stack of stars acquisition (SR-VFA-SoS) simultaneously measures temperature change using proton resonance frequency (PRF) shift and T-based thermometry methods. This work evaluates SR-VFA-SoS thermometry in MR-guided focused ultrasound in an in vivo rabbit model.

Methods: Simultaneous PRF shift thermometry and T-based thermometry were obtained in a New Zealand white rabbit model (n = 7) during MR-guided focused ultrasound surgery using the SR-VFA-SoS sequence at 3 T.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!