Objective: During assisted ventilation and spontaneous breathing, functional haemodynamic parameters, including stroke volume variation (SVV) and pulse pressure variation (PPV), are of limited value to predict fluid responsiveness, and the passive leg raising (PLR) manoeuvre has been advocated as a surrogate method. We aimed to study the predictive value of SVV, PPV and PLR for fluid responsiveness during weaning from mechanical ventilation after cardiac surgery.

Methods: Haemodynamic variables and fluid responsiveness were assessed in 34 patients. Upon arrival at the intensive care unit, measurements were performed during continuous mandatory ventilation (CMV) and spontaneous breathing with pressure support (PSV) and after extubation (SPONT). The prediction of a positive fluid responsiveness (defined as stroke volume increase >15% after fluid administration) was tested by calculating the specific receiver operating characteristic (ROC) curves.

Results: A significant increase in stroke volumes was observed during CMV, PSV and SPONT after fluid administration. There were 19 fluid responders (55.9%) during CMV, with 22 (64.7%) and 13 (40.6%) during PSV and SPONT, respectively. The predictive value for a positive fluid responsiveness (area under the ROC curve) for SVV was 0.88, 0.70 and 0.56; was 0.83, 0.69 and 0.48 for PPV; was 0.72, 0.74 and 0.70 for PLR during CMV, PSV and SPONT, respectively.

Conclusion: During mechanical ventilation, adequate prediction of fluid responsiveness using SVV and PPV was observed. However, during spontaneous breathing, the reliability of SVV and PPV was poor. In this period, PLR as a surrogate was able to predict fluid responsiveness better than SVV or PPV but was less reliable than previously reported.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937456PMC
http://dx.doi.org/10.5152/TJAR.2018.29577DOI Listing

Publication Analysis

Top Keywords

fluid responsiveness
32
svv ppv
16
stroke volume
12
predict fluid
12
mechanical ventilation
12
spontaneous breathing
12
psv spont
12
fluid
11
passive leg
8
leg raising
8

Similar Publications

Aim: This study aimed to explore the possible bidirectional interrelations between fructose-induced metabolic syndrome (MS) and apical periodontitis (AP).

Methodology: Twenty-eight male Wistar rats were distributed into four groups (n = 7, per group): Control (C), AP, Fructose Consumption (FRUT) and Fructose Consumption and AP (FRUT+AP). The rats in groups C and AP received filtered water, while those in groups FRUT and FRUT+AP received a 20% fructose solution mixed with water to induce MS.

View Article and Find Full Text PDF

: The aim of this study is to assess whether changes in Pulse Pressure Variation (PPV) and Stroke Volume Variation (SVV) following a VtC can predict the response to fluid administration in patients undergoing surgery under general anesthesia with protective mechanical ventilation. : A total of 40 patients undergoing general surgery or vascular surgery without clamping the aorta were enrolled. Protective mechanical ventilation was applied, and the radial artery was catheterized in all patients.

View Article and Find Full Text PDF

Heart and lung sharing the same anatomical space are influenced by each other. Spontaneous breathing induces dynamic changes in intrathoracic pressure, impacting cardiac function, particularly the right ventricle. In intensive care units (ICU), mechanical ventilation (MV) and therefore positive end-expiratory pressure (PEEP) are often applied, and this inevitably influences cardiac function.

View Article and Find Full Text PDF

Transducers used in acoustic logging while drilling (ALWD) must be mounted on a drill collar, and their radiation performance is dependent on the employed mounting method. Herein, the complex transmitting voltage response of a while-drilling (WD) monopole acoustic source was calculated through finite-element harmonic-response analysis. Subsequently, the acoustic pressure waveform radiated by the source driven by a half-sine excitation voltage signal was calculated using the complex transmitting voltage response.

View Article and Find Full Text PDF

Magnetic Induction Phase Difference for Cerebral Hemorrhage Detection.

Sensors (Basel)

December 2024

Department of Biomedical Engineering, Army Medical University, The Third Military Medical University, Chongqing 400038, China.

Magnetic induction phase shift is a promising technology for the detection of cerebral hemorrhage, owing to its nonradioactive, noninvasive, and real-time detection properties. To enhance the detection sensitivity and linearity, a zero-flow sensor was proposed. The uniform primary magnetic field and its counteraction were achieved.

View Article and Find Full Text PDF