This study investigated the clinical utility of an ultrasound axial transmission device in preoperative evaluation of bone quality for dental implantation, by clarifying the relationship between cortical bone speed of sound (cSOS), insertion torque values (ITV), and implant stability quotient (ISQ) in porcine femur bone. Eleven fresh porcine femurs, without soft tissue, were prepared. The cSOS of these bones were measured using the axial transmission device. Bone mineral density (BMD) and porosity (Po) were measured in cortical bone samples obtained from the region of ultrasound measurements by X-ray microcomputed tomography. Thirty-three implants were inserted into these samples (three implants per bone sample), and ITV and ISQ were measured for all implants. Then, cortical bone thickness (CbTh) of the area for implantation was measured for all implants using a micrometer. The mean cSOS was 3962 m/s; mean BMD and Po were 0.822 g/cm2 and 0.185%, respectively. cSOS and BMD values were positively correlated, and cSOS values and Po values were negatively correlated. Mean ITV, ISQ, and CbTh were 37.95 Ncm, 71.172, and 2.869 mm, respectively. There was a positive correlation between cSOS values and ISQ values. The cSOS of each bone did not correlate with ITV for all of the bone samples. However, when the CbTh ranges from 3.0 to 3.5 mm, ITV are correlated with cSOS. These findings suggest that cSOS, which reflects the cortical bone quality, may be clinical utility as a preoperative diagnosis of the implant.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5719822PMC
http://dx.doi.org/10.1002/cre2.59DOI Listing

Publication Analysis

Top Keywords

cortical bone
16
bone quality
12
axial transmission
12
transmission device
12
bone
11
csos
9
preoperative evaluation
8
evaluation bone
8
quality dental
8
dental implantation
8

Similar Publications

Background Odontogenic maxillary sinusitis arises mainly from dental origins, emphasizing the connection between dental health and sinus issues. Understanding these relationships is crucial for implant planning, sinus augmentation procedures, and managing post-extraction complications. This knowledge can help clinicians make informed decisions about treatment timing and approach.

View Article and Find Full Text PDF

Postoperative bone resorption within the first year after a free fibular flap is a common problem and poses major challenges for subsequent therapies. Due to the concerns of increased bone resorption, short segments in particular, i.e.

View Article and Find Full Text PDF

: This study aimed to explore how the microarchitectural features of lacunae and perilacunar zones impact the biomechanics of microdamage accumulation in cortical bone, crucial for understanding bone disorders' pathogenesis and developing preventive measures. : Utilizing the phase field finite element method, the study analyzed three bone unit models with varying microarchitecture: one without lacunae, one with lacunae and one including perilacunar zones, to assess their effects on cortical bone's biomechanical properties. : The presence of lacunae was found to increase microcrack initiation risk, acting as nucleation points and accelerating microcrack propagation.

View Article and Find Full Text PDF

Exploration of the dynamics of otic capsule and intracochlear pressure: Numerical insights with experimental validation.

J Acoust Soc Am

January 2025

Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

The otic capsule and surrounding temporal bone exhibit complex 3D motion influenced by frequency and location of the bone conduction stimulus. The resultant correlation with the intracochlear pressure is not sufficiently understood, thus is the focus of this study, both experimentally and numerically. Experiments were conducted on six temporal bones from three cadaver heads, with BC hearing aid stimulation applied at the mastoid and classical BAHA locations across 0.

View Article and Find Full Text PDF

Purpose: Few studies have explored the bone response in dental implant sites prepared using a piezoelectric device, indicating moderate effectiveness in enhancing secondary stability and osteogenesis. This study seeks to expand our understanding of the changes in biological, clinical, and radiographic parameters, during the initial phases of osseointegration in sites prepared with piezoelectric surgery.

Materials And Methods: Two implant sites were prepared in the tibia of four minipigs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!