A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Can point shear wave elastography differentiate focal nodular hyperplasia from hepatocellular adenoma. | LitMetric

Purpose: Focal nodular hyperplasia (FNH) and hepatocellular adenoma (HCA) are liver tumors that require different management. We assessed the potential of point shear wave elastography (pSWE) to differentiate FNH from HCA and the interobserver and intraobserver reliability of pSWE in the examination of these lesions and of native liver tissue (NLT).

Methods: The study included 88 patients (65 FNH, 23 HCA). pSWE was performed by two experienced liver sonographers (observers 1 [O1] and 2 [O2]) and acquired within the lesion of interest and NLT. Group differences, optimal cutoff for characterization and interobserver reliability was assessed with Mann-Whitney-U, area under the ROC curce (AUROC) and intraclass correlation coefficient (ICC). Intraobserver reliability in NLT was assessed in 20 healthy subjects using ICC.

Results: Median stiffness was significantly higher in FNH than in HCA (7.01 kPa vs 4.98 kPa for O1 (P = 0.017) and 7.68 kPa vs 6.00 kPa for O2 (P = 0.031)). A cutoff point for differentiation between the two entities could not be determined with an AUROC of 0.67 (O1) and 0.69 (O2). Interobserver reliability was good for lesion- stiffness (ICC = 0.86) and poor for NLT stiffness (ICC = 0.09). In healthy subjects, intraobserver reliability for NLT-stiffness was poor for O1 (ICC = 0.23) and moderate for O2 (ICC = 0.62).

Conclusion: This study shows that pSWE cannot reliably differentiate FNH from HCA. Interobserver and intraobserver reliability for pSWE in NLT were insufficient. Interpretation of results gained with this method should be done with great caution.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6033170PMC
http://dx.doi.org/10.1002/jcu.22603DOI Listing

Publication Analysis

Top Keywords

fnh hca
16
intraobserver reliability
16
point shear
8
shear wave
8
wave elastography
8
focal nodular
8
nodular hyperplasia
8
hepatocellular adenoma
8
differentiate fnh
8
hca interobserver
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!