Aptamers are oligonucleotide receptors obtained through an iterative selection process from random-sequence libraries. Though many aptamers for a broad range of targets with high affinity and selectivity have been generated, a lack of high-resolution structural data and the limitations of currently available biophysical tools greatly impede understanding of the mechanisms of aptamer-ligand interactions. Here we demonstrate that an approach based on native electrospray ionization mass spectrometry (ESI-MS) can be successfully applied to characterize aptamer-ligand complexes in all details. We studied an adenosine-binding aptamer (ABA), a l-argininamide-binding aptamer (LABA), and a cocaine-binding aptamer (CBA) and their noncovalent interactions with ligands by native ESI-MS and complemented these measurements by ion mobility spectrometry (IMS), isothermal titration calorimetry (ITC), and circular dichroism (CD) spectroscopy. The ligand selectivity of the aptamers and the respective complex stoichiometry could be determined by the native ESI-MS approach. The ESI-MS data can also help refining the binding model for aptamer-ligand complexes and deliver accurate aptamer-ligand binding affinities for specific and nonspecific binding events. For specific ligands, we found K = 69.7 μM and K = 5.3 μM for ABA (two binding sites); K = 22.04 μM for LABA; and K = 8.5 μM for CBA.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jacs.7b13044DOI Listing

Publication Analysis

Top Keywords

native electrospray
8
electrospray ionization
8
ionization mass
8
mass spectrometry
8
aptamer-ligand interactions
8
aptamer-ligand complexes
8
native esi-ms
8
aptamer-ligand
5
binding
5
native
4

Similar Publications

The outer mitochondrial membrane protein known as mitoNEET was discovered when it was labeled by a photoaffinity derivative of the anti-diabetes medication, pioglitazone. The biological role for mitoNEET and its specific mechanism for achieving this remains an active subject for research. There is accumulating evidence suggesting that mitoNEET could be a component of mitochondrial FeS cofactor biogenesis.

View Article and Find Full Text PDF

FAST MS: Software for the Automated Analysis of Top-Down Mass Spectra of Polymeric Molecules Including RNA, DNA, and Proteins.

J Am Soc Mass Spectrom

December 2024

Institute of Organic Chemistry and Center for Molecular Biosciences Innsbruck (CMBI), University of Innsbruck, 6020 Innsbruck, Austria.

Top-down mass spectrometry (MS) enables comprehensive characterization of modified proteins and nucleic acids and, when native electrospray ionization (ESI) is used, binding site mapping of their complexes with native or therapeutic ligands. However, the high complexity of top-down MS spectra poses a serious challenge to both manual and automated data interpretation, even when the protein, RNA, or DNA sequence and the type of modification or the ligand are known. Here, we introduce FAST MS, a user-friendly software that identifies, assigns and relatively quantifies signals of molecular and fragment ions in MS and MS/MS spectra of biopolymers with known sequence and provides a toolbox for statistical analysis.

View Article and Find Full Text PDF

Comparison of Partially Denatured Cytochrome Structural Ensembles in Solution and Gas Phases Using Cross-Linking Mass Spectrometry.

J Am Soc Mass Spectrom

December 2024

Department of Chemistry and Chemical Biology, Indiana University─Indianapolis, Indianapolis, Indiana 46202, United States.

Electrospray ionization mass spectrometry (ESI-MS) can retain intact protein structures, but details about partially folded and unfolded protein structures during and after introduction to the gas phase are elusive. Here we use ESI-MS with chemical cross-linkers to compare denatured cytochrome structures in both solution and gas phases. Solution phase cross-linking prior to ESI captures solution phase structures, while gas phase cross-linking through ion/ion reactions in the trap cell captures gas phase structures.

View Article and Find Full Text PDF

The goal of native mass spectrometry is to obtain information on noncovalent interactions in solution through mass spectrometry measurements in the gas phase. Characterizing intramolecular folding requires using structural probing techniques such as ion mobility spectrometry. However, inferring solution structures of nucleic acids is difficult because the low-charge state ions produced from aqueous solutions at physiological ionic strength get compacted during electrospray.

View Article and Find Full Text PDF

Native mass spectrometry analysis of proteins directly from tissues can be performed by using nanospray-desorption electrospray ionization (nano-DESI). Typically, supplementary collisional activation is essential to decluster protein complex ions from solvent, salt, detergent, and lipid clusters that comprise the ion beam. As an alternative, we have implemented declustering by infrared (IR) photoactivation on a linear ion trap mass spectrometer equipped with a CO laser (λ = 10.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!