Aim: To prospectively evaluate the accuracy of cardiac magnetic resonance (cMR) imaging for the assessment of aortic valve effective orifice area (EOA) by continuity equation and anatomical aortic valve area (AVA) by direct planimetry, as compared with transthoracic (TTE) and transesophageal (TEE) two-dimensional (2D) echocardiography, respectively.
Methods And Results: A total of 31 patients (21 men, 10 women, mean age 69 ± 10 years) with moderate-to-severe aortic stenosis (AS) diagnosed by TTE and scheduled for elective aortic valve replacement, underwent both cMR and TEE. AVA by cMR was obtained from balanced steady-state free-precession cine-images. EOA was computed from phase-contrast MR flow analysis. AVA at cMR (0.93 ± 0.42 cm) was highly correlated with TEE-derived planimetry (0.92 ± 0.32 cm) (concordance correlation coefficient, CCC = 0.85). By excluding 11 patients with extensively thickened and heavily calcified cusps, the CCC increased to 0.93. EOA at cMR (0.86 ± 0.30 cm) showed a strong correlation with TTE-derived EOA (0.78 ± 0.25 cm) (CCC = 0.82).
Conclusions: cMR imaging is an accurate alternative for the grading of AS severity. Its use may be recommended especially in patients with poor transthoracic acoustic windows and/or in case of discordance between 2D echocardiographic parameters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11547-018-0895-2 | DOI Listing |
Eur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Eur Heart J Case Rep
January 2025
Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, North Kargar Ave, Tehran 1411713138, Iran.
Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.
View Article and Find Full Text PDFCJC Open
January 2025
Department of Cardiology, Royal North Shore Hospital, Sydney, Australia.
CJC Open
January 2025
Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Mexico City, Mexico.
Australas J Ultrasound Med
February 2025
Department of Medicine, Otago School of Medicine Otago University Dunedin New Zealand.
Rheumatic heart disease remains prevalent in some regions of Australia and New Zealand. Echocardiography is the gold standard for detection and diagnosis using the 2023 World Heart Federation guidelines. The guidelines describe specific features of mitral and aortic valve morphology and define pathological regurgitation associated with RHD.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!