A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design of Hollow Hyaluronic Acid Cylinders for Sustained Intravitreal Protein Delivery. | LitMetric

Design of Hollow Hyaluronic Acid Cylinders for Sustained Intravitreal Protein Delivery.

J Pharm Sci

Department of Chemical and Petroleum Engineering, University of Kansas, Lawrence, Kansas 66045; Bioengineering Program, University of Kansas, Lawrence, Kansas 66045. Electronic address:

Published: September 2018

A hollow cylinder intravitreal implant was developed to achieve sustained release of protein to the retina for the treatment of retinal diseases. Hollow cylinders were fabricated by molding and cross-linking hyaluronic acid, the major component of the vitreous humor. Hollow cylinders were filled with a concentrated protein solution, and the properties of the cylinder walls were tested. Cross-linked hyaluronic acid hydrogels with swelling degrees as low as 2.7 were achieved as a means to extend the release of protein. Hollow cylinders were capable of releasing an antigen-binding fragment for over 4 months at a maximum release rate of 4 μg per day. Protein release from hollow cylinders was modeled using COMSOL Multiphysics software, and diffusion coefficients between 1.0 × 10 and 3.0 × 10 cm/s yielded therapeutically effective levels of protein. Cylinders with a 1 mm outer radius were capable of loading >1 mg of protein while releasing at least 2.5 μg a day for over 4.5 months. Although smaller cylinders facilitate intravitreal placement, decreasing the cylinder radius severely limited drug loading. Design of hollow cylinder intravitreal implants must balance high drug loading to reduce device size with control of the diffusion coefficient to sustain protein release.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.xphs.2018.04.024DOI Listing

Publication Analysis

Top Keywords

hollow cylinders
16
hyaluronic acid
12
design hollow
8
protein
8
hollow cylinder
8
cylinder intravitreal
8
release protein
8
μg day
8
protein release
8
drug loading
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!