BACKGROUND This study was designed to determine diagnostic accuracy of computed tomographic perfusion (CTP) compared to computed tomographic angiography (CTA) for the diagnosis of brain death (BD). MATERIAL AND METHODS Whole-brain CTP was performed in patients diagnosed with BD and in patients with devastating brain injury with preserved brainstem reflexes. CTA was derived from CTP datasets. Cerebral blood flow (CBF) and volume (CBV) were calculated in all brain regions. CTP findings were interpreted as confirming diagnosis of BD (positive) when CBF and CBV in all ROIs were below 10 mL/100 g/min and 1.0 mL/100 g, respectively. CTA findings were interpreted using a 4-point system. RESULTS Fifty brain-dead patients and 5 controls were included. In brain-dead patients, CTP results revealed CBF 0.00-9.98 mL/100 g/min and CBV 0.00-0.99 mL/100 g, and were thus interpreted as positive in all patients. CTA results suggested 7 negative cases, providing 86% sensitivity. In the non-brain-dead group, CTP results revealed CBF 2.37-37.59 mL/100 g/min and CBV 0.73-2.34 mL/100 g. The difference between values of CBF and CBV in the brain-dead and non-brain-dead groups was statistically significant (p=0.002 for CBF and p=0.001 for CBV). CTP findings in all non-brain-dead patients were interpreted as negative. This resulted in a specificity of 100% (95% CI, 0.31-1.00) for CTP in the diagnosis of BD. In all non-brain-dead patients, CTA revealed preserved intracranial filling and was interpreted as negative. This resulted in a specificity of 100% (95% CI, 0.31-1.00) for CTA in diagnosis of BD. CONCLUSIONS Whole-brain CTP seems to be a highly sensitive and specific method in diagnosis of BD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5957092PMC
http://dx.doi.org/10.12659/MSM.906304DOI Listing

Publication Analysis

Top Keywords

computed tomographic
12
ml/100 g/min
12
ctp
9
accuracy computed
8
tomographic perfusion
8
diagnosis brain
8
brain death
8
cta diagnosis
8
whole-brain ctp
8
ctp findings
8

Similar Publications

Transcatheter Aortic Valve Replacement in Patients With Interventricular Membranous Septal Aneurysms.

JACC Case Rep

January 2025

Interventional Cardiology Section, Division of Cardiovascular Medicine, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA.

Aneurysms of the interventricular membranous septum are a rare anatomical feature that can be detected incidentally on computed tomography or echocardiography. Such aneurysms can pose challenges in the treatment of patients with aortic valve stenosis. A case series of 2 patients with membranous septal aneurysms treated successfully with current-generation balloon-expandable and self-expanding transcatheter heart valves is presented here.

View Article and Find Full Text PDF

Objective: To evaluate the application value of CT diagnostic technology based on the Shukun Imaging Post-Processing System for early screening and diagnosis of lung cancer.

Methods: A total of 35 patients diagnosed with lung cancer postoperatively and 53 patients with benign nodules were included in this retrospective study, all of whom were treated in the Department of Thoracic and Cardiovascular Surgery of the Second Affiliated Hospital of Fujian Medical University from January 2020 to December 2023. All patients underwent chest spiral CT examinations.

View Article and Find Full Text PDF

Isolated fallopian tube torsion (IFTT) is a rare cause of surgical emergency and is difficult to diagnose. We present a case of IFTT in a 14-year-old girl who presented with an acute abdomen. Based on the clinical and computed tomographic findings, an initial diagnosis of ovarian torsion was considered.

View Article and Find Full Text PDF

With the advancement in imaging technology, ECG-gated cardiac multidetector computed tomography (MDCT) has emerged as a tool for the anatomic evaluation of the pulmonary valve and right ventricular outflow tract (RVOT) in human medicine. Currently, the evaluation of the pulmonary valve relies primarily on echocardiographic examination. However, the bi-dimensional nature of this technique and the location/orientation of the pulmonary valve in the thoracic cavity can pose challenges.

View Article and Find Full Text PDF

Clinically, the rodent thorax is important because of the variety of problems that may affect the heart, lungs, and other thoracic structures. Syrian hamsters are the most common pet and experimental hamster species. Sectional imaging of small mammals is widely increasing in use for clinical and research settings; however, no reports on the thoracic sectional imaging anatomy in this species have been made.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!