Introduction: The aim of the study was to evaluate complications of cataract surgery in eyes filled with silicone oil.

Methods: This retrospective, noncomparative, consecutive case series analyzed medical files of patients with eyes filled with silicone oil undergoing cataract surgery. Phacoemulsification with posterior chamber intraocular lens implantation was conducted with or without concurrent silicone oil removal.

Results: In this study, 121 eyes of 120 patients were included. In 32 eyes (26.4%) with evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, silicone oil was removed prior to phacoemulsification through a pars plana incision and no cases of posterior capsular rupture occurred during the subsequent cataract surgery. In the remaining 89 eyes, phacoemulsification was performed with silicone oil in the vitreous cavity. In these eyes, the rate of posterior capsular rupture was 9/89 (10.1%) and the rate of silicone oil migration into the anterior chamber through an apparently intact posterior capsule was 5/89 (5.6%). In 94 eyes (77.7%), an intraocular lens was inserted into the capsular bag, in 3 eyes (2.5%) into the sulcus, and in 1 eye (0.8%) a transscleral suturing was performed.

Conclusions: In this series, complications related to the silicone oil were not uncommon during cataract surgery. In the majority of patients without evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, cataract surgery and posterior chamber intraocular lens implantation were performed while leaving the silicone oil in place.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1120672117753700DOI Listing

Publication Analysis

Top Keywords

silicone oil
40
cataract surgery
24
silicone
13
eyes filled
12
filled silicone
12
intraocular lens
12
oil
10
eyes
9
complications cataract
8
surgery eyes
8

Similar Publications

Purpose: To evaluate preoperative and early postoperative factors associated with changes in visual acuity in macula-off rhegmatogenous retinal detachment (RRD) patients.

Methods: A retrospective review of 59 eyes from 59 patients who underwent pars plana vitrectomy (PPV) and silicone oil (SiO) tamponade for macula-off RRD. Preoperative and early postoperative characteristics were analyzed using the classification and regression tree (CART) analysis.

View Article and Find Full Text PDF

Plasmonic Slippery Surface for Surface-Enhanced Raman Spectroscopy and Protein Adsorption Inhibition.

Anal Chem

January 2025

Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal 576104, India.

Slippery liquid-infused porous surfaces (SLIPSs) are a class of surface that offers low contact angle hysteresis and low tilt angle for water droplet shedding. This property also endows the surface with pinning-free evaporation, which in turn has been exploited for analyte concentration enrichment for Surface Enhanced Raman Spectroscopic applications and antibiofouling. Herein, we demonstrate a facile approach for creating SLIPS with low contact angle hysteresis and low tilt angle for water shedding by coating the equal-volume mixture of polydimethylsiloxane (PDMS) and silicone oil.

View Article and Find Full Text PDF

Purpose: Human amniotic membrane (hAM) grafts have been used to close persistent macular holes in recent years. The results from these surgeries are promising with improved closure rate and vision. However, there is lack of data for what happens to these membranes and how long the tissue should remain inside the patient's eyes.

View Article and Find Full Text PDF

Retinal graft dislocation managed by repeat autologous retinal transplant for refractory macular hole.

BMJ Case Rep

January 2025

Smt. Kanuri Santhamma Centre for Vitreo Retinal Diseases, Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, Telangana, India

A septuagenarian man presented with a visual acuity of hand motions and a large refractory macular hole (MH). We performed an autologous retinal transplant (ART) and covered the graft with fibrin glue without any endotamponade. The autograft was found to have dislocated from the MH when the patient was reviewed 1 week later.

View Article and Find Full Text PDF

Background: To report clinical outcomes from a single-center cohort undergoing PAUL® Glaucoma Implant (PGI) surgery for secondary glaucoma after vitreoretinal surgery (VR).

Methods: Retrospective review of patients undergoing PGI surgery at the University Eye Hospital Bonn, Germany, from 04/2021 to 05/2023.

Results: 33 eyes of 33 patients were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!