A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Microbiological aspects of thermophile pretreatment of activated sludge inhibiting electricity generation of microbial fuel cell. | LitMetric

Microbiological aspects of thermophile pretreatment of activated sludge inhibiting electricity generation of microbial fuel cell.

Water Sci Technol

Shandong Provincial Key Laboratory of Marine Environment and Geological Engineering (MEGE), College of Environmental Science and Engineering, Ocean University of China, Qingdao 266100, China E-mail: Key Laboratory of Marine Environment and Ecology (Ocean University of China), Ministry of Education, Qingdao 266100, China.

Published: May 2018

Thermophile pretreatment of activated sludge greatly improves the biodegradability of sludge, but whether the pretreated products are suitable for the electricity generation of microbial fuel cells (MFCs) is still little known. In this study, municipal activated sludge pretreated by a thermophilic bacterium and heating, respectively, was separately fed into the MFCs. The performance of MFCs was examined and changes of anodic microbial communities were investigated with scanning electron microscopy and 16S rRNA gene high-throughput sequencing on the Illumina Miseq platform. The results showed that MFCs fed with heating-pretreated sludge performed preferably and the power density reached 0.91-2.86 W/m. MFC anodes were covered with considerable Geobacter spp. However, the bioaugmentation of sludge with the thermophile was not able to support a high potential output although the pretreatment significantly increased the soluble chemical oxygen demand. The maximum power density approached 0.20 W/m even when the anolyte was regularly changed. It was observed that amending pH did not improve the performance of MFC. Investigation on this anodic microbial community found that the relative abundance of Lactobacillus spp. exceeded 91%. Consequently, the thermophile-pretreated products stimulated the growth of non-exoelectrogens and finally the niches of anodic biofilm were completely occupied by Lactobacillus spp.

Download full-text PDF

Source
http://dx.doi.org/10.2166/wst.2018.130DOI Listing

Publication Analysis

Top Keywords

activated sludge
12
thermophile pretreatment
8
pretreatment activated
8
electricity generation
8
generation microbial
8
microbial fuel
8
sludge pretreated
8
anodic microbial
8
power density
8
lactobacillus spp
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!