Electro-optic dual-comb spectrometers have proved to be a promising technology for sensitive, high-resolution and rapid spectral measurements. Electro-optic combs possess very attractive features like simplicity, reliability, bright optical teeth, and typically moderate but quickly tunable optical spans. Furthermore, in a dual-comb arrangement, narrowband electro-optic combs are generated with a level of mutual coherence that is sufficiently high to enable optical multiheterodyning without inter-comb stabilization or signal processing systems. However, this valuable tool still presents several limitations; for instance, on most systems, absolute frequency accuracy and long-term stability cannot be guaranteed; likewise, interferometer-induced phase noise restricts coherence time and limits the attainable signal-to-noise ratio. In this paper, we address these drawbacks and demonstrate a cost-efficient absolute electro-optic dual-comb instrument based on a frequency stabilization mechanism and a novel adaptive interferogram acquisition approach devised for electro-optic dual-combs capable of operating in real-time. The spectrometer, completely built from commercial components, provides sub-ppm frequency uncertainties and enables a signal-to-noise ratio of 10000 (intensity noise) in 30 seconds of integration time.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.26.009700 | DOI Listing |
We demonstrate spatially resolved sensing by a novel approach that combines an infrared camera and a simplified dual-comb illumination arrangement. Specifically, our scheme employs a continuous-wave laser and only one electro-optic modulator to simultaneously create a pair of mutually coherent optical frequency combs, each one with a slightly different line spacing. The system operates by measuring this dual-comb spectrum from a sequence of acquired images, in order to recover the spectral response of every spatial point of a sample.
View Article and Find Full Text PDFIn this Letter, we propose a high-resolution dual-comb spectroscopy (DCS) in the mid-infrared (MIR) region. A broadband electro-optic frequency comb (EOFC) with a line spacing of 13 GHz is generated in the near-infrared region. The injection locking technique is employed to lock the distributed feedback (DFB) laser to each comb line of the 34 comb lines as the seed laser for the subsequent electro-optic modulation.
View Article and Find Full Text PDFWe present the development of a multi-spectral, integrated-path differential absorption (IPDA) lidar based on a dual-comb spectrometer for greenhouse gas monitoring. The system uses the lidar returns from topographic targets and does not require retroreflectors. The two frequency combs are generated by electro-optic modulation of a single continuous-wave laser diode.
View Article and Find Full Text PDFNat Commun
December 2023
Univ. Lille, CNRS, UMR 8523-PhLAM-Physique des Lasers Atomes et Molécules, F-59000, Lille, France.
Tricomb spectroscopy unveils a new dimension to standard linear and nonlinear spectroscopic analysis, offering the possibility to reveal the almost real-time evolution of complex systems with unprecedented accuracy. Current triple comb configurations are based on the use of mode-locked lasers, which impose constraints on the comb parameters, and require complex electronic synchronization, thus limiting potential applications. In this paper, we present the experimental demonstration of a new type of all-fiber, self-phase-locked, frequency-agile tri-comb light source.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!