Background And Aims: MRI can detect intracranial vessel wall thickening before any luminal stenosis is present. Apart from representing a vessel wall lesion, wall thickening could also reflect normal (age-related) variations in vessel wall thickness present throughout the intracranial arterial vasculature. The aim of this study was to perform vessel wall thickness measurements of the major intracranial arteries in ex vivo circle of Willis (CoW) specimens using 7T MRI, to obtain more detailed information about wall thickness variations of the intracranial arteries.
Methods: Fifteen human CoW specimens were scanned at 7T MRI with an ultrahigh-resolution T-weighted sequence. Five specimens were used for validation of MRI measurements with histology and evaluation of inter-rater reliability and agreement. The other 10 specimens from patients with (n = 5) and without (n = 5) cerebrovascular disease were used for vessel wall thickness measurements over the entire length of the major arterial segments of the CoW using MRI only.
Results: MRI measurements showed excellent agreement with histology. Mean wall thickness varied from 0.45 to 0.66 mm, minimum wall thickness from 0.31 to 0.42 mm, maximum wall thickness from 0.52 to 0.86 mm, and normalized wall index from 0.64 to 0.75. On average, vessel walls were thicker for symptomatic patients compared to asymptomatic patients.
Conclusions: High-resolution MRI enables accurate measurement of vessel wall thickness in ex vivo CoW specimens. Vessel wall thickness measurements over the entire length of segments showed considerable variation both within and between arterial segments of patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.atherosclerosis.2018.04.023 | DOI Listing |
Rev Cardiovasc Med
January 2025
Department of Echocardiography and Cardiology, The First People's Hospital of Changzhou, 213003 Changzhou, Jiangsu, China.
Background: This article focuses on the effect of body mass index (BMI) on cardiac structure and function in cases with non-valvular atrial fibrillation (NVAF). Only a few articles have investigated the relationship between BMI and the incidence of left atrial thrombus (LAT) or spontaneous echo contrast (SEC) in cases with NVAF.
Methods: This single-center retrospective study was conducted at The First People's Hospital of Changzhou.
Cureus
December 2024
Obstetrics and Gynecology, Marunouchi Hospital, Matsumoto, JPN.
Malignant transformation is a rare complication of ovarian mature cystic teratoma that occurs in 1-3% of cases. We herein report a case of squamous cell carcinoma originating from mature cystic teratoma of the ovary diagnosed 10 years after initial tumor detection. A 69-year-old woman presented to the Department of Internal Medicine with a seven-month history of abdominal fullness.
View Article and Find Full Text PDFZhonghua Yi Xue Za Zhi
January 2025
Department of Urology, Henan Joint International Pediatric Urodynamic Laboratory, the First Affiliated Hospital of Zhengzhou University, Zhengzhou450002, China.
To comprehensively evaluate the structure and function of the bladder wall in children using multi-modal ultrasound (MMU). A total of 110 children without urinary symptoms admitted to the First Affiliated Hospital of Zhengzhou University from January 2022 to June 2023 were included prospectively. MMU was performed and the vesical volume (VV), bladder wall thickness (BWT), shear wave velocity (SWV) of the anterior wall, resistance index (RI) and vascularization index (VI) were measured in the filled and emptied bladder respectively, and the ultrasound bladder compliance (UBC) was also calculated.
View Article and Find Full Text PDFLife Sci Space Res (Amst)
February 2025
Division of Radiation Health, Department of Pharmaceutical Sciences, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA.
Future long duration space missions will expose astronauts to higher doses of galactic cosmic radiation (GCR) than those experienced on the international space station. Recent studies have demonstrated astronauts may be at risk for cardiovascular complications due to increased radiation exposure and fluid shift from microgravity. However, there is a lack of direct evidence on how the cardiovascular system is affected by GCR and microgravity since no astronauts have been exposed to exploratory mission relevant GCR doses.
View Article and Find Full Text PDFHeart Rhythm
January 2025
Division of Cardiology, Department of Medicine, Nihon University School of Medicine Tokyo Japan. Electronic address:
Background: Pulsed field ablation (PFA) for paroxysmal atrial fibrillation (AF) has been gaining worldwide acceptance due to its efficacy and safety. A variable loop circular catheter (VLCC, VARIPULSE, Biosense Webster, Inc.) for PFA, recently launched in Japan, includes a Tissue Proximity Indication (TPI) feature to monitor catheter-tissue contact via impedance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!