Background: Midshaft clavicle fractures are often associated with a certain degree of shortening. There is great variety in the imaging techniques and methods to quantify this shortening. This study aims to quantify the difference in measurements of shortening and length of fracture elements between 5 views of the fractured clavicle. Furthermore, the interobserver and intraobserver agreement between these views using a standardized method is evaluated.

Materials And Methods: Digitally reconstructed radiographs were created for 40 computed tomography datasets in the anteroposterior (AP), 15° and 30° craniocaudal, and 15° and 30° caudocranial views. A standardized method for measuring the length of fracture elements and the amount of shortening was used. Interobserver and intraobserver agreement for each of the 5 views was calculated.

Results: The interobserver and intraobserver agreement was excellent for all 5 views, with all intraclass correlation coefficient values greater than 0.75. The measured differences in relative and absolute shortening between views were statistically significant between the 30° caudocranial view and all other views. The increase in median shortening measured between the commonly used 30° caudocranial view (2.7 mm) and the AP view (8.5 mm) was 5.8 mm (P < .001). The relative median shortening between these views increased by 3.5% (P < .001).

Conclusion: The length of fracture elements and the amount of shortening in the fractured clavicle can be reliably measured using a standardized method. The increase in absolute and relative shortening when comparing the caudocranial measurements with the AP and craniocaudal measurements may indicate that the AP and craniocaudal views provide a more accurate representation of the degree of shortening.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2018.02.054DOI Listing

Publication Analysis

Top Keywords

interobserver intraobserver
12
intraobserver agreement
12
30° caudocranial
12
fractured clavicle
8
length fracture
8
fracture elements
8
agreement views
8
views standardized
8
standardized method
8
15° 30°
8

Similar Publications

Purpose: No studies have explored the reliability of the Rigo classification system using surface topography (ST), which would allow optimization without radiation exposure. This study aims to measure and compare the intra- and inter-observer reliability (Kappa values) and accuracy of the Rigo system between ST and X-ray for overall types and subtypes.

Methods: X-ray and ST images of 31 adolescent idiopathic scoliosis patients were selected.

View Article and Find Full Text PDF

Objectives: Multiple techniques have been proposed for functional fetal cardiology, including pulsed-wave (PW) and tissue Doppler imaging (TDI), Myocardial Performance Index (MPI), annular plane systolic excursion (TAPSE/MAPSE) and spatiotemporal image correlation (STIC). We aimed to compare these techniques' achievability and reproducibility to determine their clinical utility for each cardiac side.

Methods: Uncomplicated pregnancies from 22 to 39 weeks were recruited and images and volumes stored for offline analysis.

View Article and Find Full Text PDF

Background: Mobilization of the subscapularis muscle (SSC) is crucial for optimal access to the glenohumeral joint during anatomical total shoulder arthroplasty (ATSA). However, the ideal mobilization technique remains controversial. This study aimed to assess the impact of the lesser tuberosity C-block osteotomy, a modified lesser tuberosity osteotomy, on the postoperative subscapularis (SSC) volume following anatomical shoulder arthroplasty and compare it to the volume of the infraspinatus/teres minor.

View Article and Find Full Text PDF

Patient-specific templating (PST), which is a sister procedure to patient-specific instrumentation (PSI) but hospital-based, is relatively less complex and less expensive than robotics and navigation. However, there are some concerns about the PST including the process of preoperative planning, 3D printing and material, positioning of PST intraoperatively, availability, and clinical value. The purpose of this study was to validate the technical accuracy and reliability of the PST technique in the lab and to report the outcomes of clinical application.

View Article and Find Full Text PDF

Subject-specific parameters in lumped hemodynamic models of the cardiovascular system can be estimated using data from experimental measurements, but the parameter estimation may be hampered by the variability in the input data. In this study, we investigate the influence of inter-sequence, intra-observer, and inter-observer variability in input parameters on estimation of subject-specific model parameters using a previously developed approach for model-based analysis of data from 4D Flow MRI acquisitions and cuff pressure measurements. The investigated parameters describe left ventricular time-varying elastance and aortic compliance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!