Objective: To understand the validity and reliability of consumer-grade activity trackers (consumer wearables) in older, community-dwelling adults.

Methods: A systematic review of studies involving adults aged over 65 years who underwent physical activity monitoring with consumer wearables. A total of 7 observational studies qualified, identified from electronic databases: MEDLINE, EMBASE, Cochrane Library and others (2014-2018). Validity was interpreted using correlation coefficients (CC) and percentage error for agreement between reference devices or gold-standard validation methods Reliability was compared using mean differences or ranges (under- or overestimation) of step count and activity time.

Results: Total sample size was 290 adults, mean age of 70.2 ± 4.8 years and females constituting 46.7 ± 26.1%. The studies evaluated eight different consumer wearables used by community-dwelling adults with a range of co-morbidities. Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine. Slower walking pace and impaired ambulation reduced the levels of agreement. Daily step count captured by Fitbit Zip was on average 7117 (±5,880.6), which was overestimated by five of the eight consumer wearables compared with reference devices (range 167.6-2,690.3 steps/day). Measurement of activity duration was accurate compared with reference devices, yet less so than step count.

Conclusion: In older, community-dwelling adults, consumer wearables accurately measure step count and activity duration, as confirmed by reference devices and validation methods Further research is required to understand how co-morbidities, gait and activity levels interact with monitoring in free-living environments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.maturitas.2018.03.016DOI Listing

Publication Analysis

Top Keywords

consumer wearables
24
reference devices
16
step count
16
older community-dwelling
12
community-dwelling adults
12
validity reliability
8
reliability consumer-grade
8
consumer-grade activity
8
activity trackers
8
systematic review
8

Similar Publications

Atrial arrhythmias, including atrial fibrillation (AF), are a major contributor to cardiovascular morbidity and mortality. Early detection and effective management are critical to mitigating adverse outcomes such as stroke, heart failure, and overall mortality. Wearable devices have emerged as promising tools for monitoring, detecting, and managing atrial arrhythmias near-continuously.

View Article and Find Full Text PDF

Over the past ten years, there has been an increasing demand for reliable consumer wearables as users are inclined to monitor their health and fitness metrics in real-time, especially since the COVID-19 pandemic. Reflectance pulse oximeters in fitness trackers and smartwatches provide convenient, non-invasive SpO measurements but face challenges in achieving medical-grade accuracy, particularly due to difficulties in capturing physiological signals, which may be affected by skin pigmentation. Hence, this study sets out to investigate the influence of skin pigmentation, particularly in individuals with darker skin, on the accuracy and reliability of SpO measurement in consumer wearables that utilise reflectance pulse oximeters.

View Article and Find Full Text PDF

MEMS acoustic sensors are a type of physical quantity sensor based on MEMS manufacturing technology for detecting sound waves. They utilize various sensitive structures such as thin films, cantilever beams, or cilia to collect acoustic energy, and use certain transduction principles to read out the generated strain, thereby obtaining the targeted acoustic signal's information, such as its intensity, direction, and distribution. Due to their advantages in miniaturization, low power consumption, high precision, high consistency, high repeatability, high reliability, and ease of integration, MEMS acoustic sensors are widely applied in many areas, such as consumer electronics, industrial perception, military equipment, and health monitoring.

View Article and Find Full Text PDF

With the emergence of the Internet of Things (IoT), the demand on the wireless power supply to consumer electronics simultaneously requires much more location freedom, ease of use, and performance with wireless communications. In this paper, an unenclosed quasi-static cavity resonator (QSCR) constructed with metallic strips and the design method are proposed and theoretically analyzed. This unenclosed QSCR has a simple structure, which benefits the wireless charging for portable/wearable electronics and smart appliances in the office and home environment.

View Article and Find Full Text PDF

Background: The prompt and accurate identification of mild cognitive impairment (MCI) is crucial for preventing its progression into more severe neurodegenerative diseases. However, current diagnostic solutions, such as biomarkers and cognitive screening tests, prove costly, time-consuming, and invasive, hindering patient compliance and the accessibility of these tests. Therefore, exploring a more cost-effective, efficient, and noninvasive method to aid clinicians in detecting MCI is necessary.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!