Pneumococcal conjugate vaccines (PCVs) have been very effective in reducing the disease burden caused by Streptococcus pneumoniae serotypes covered by the current vaccine formulations. However, the incidence of disease caused by serotypes not covered by the vaccine is increasing. Consequently, there are active efforts to develop new PCVs with additional serotypes in order to provide protection against the emergent serotypes. Due to costs and ethical issues associated with performing true vaccine efficacy studies, new PCVs are being licensed based on their immunogenicity, which may be assessed with 2 in vitro assays: enzyme-linked immunosorbent assay (ELISA) for quantitating antibody level and opsonophagocytic assay (OPA) for assessing protective function. While a standardized ELISA has been developed, OPA results from different laboratories can be quite disparate, even among laboratories utilizing the same platform. In order to harmonize OPA data, a recent international collaboration assigned opsonic indices to the US Food and Drug Administration (US FDA) reference serum, 007sp, as well as a panel of US FDA calibration sera. However, due to a low number of aliquots, the availability of these calibration sera is extremely limited. Because calibration sera are critical to establish the performance characteristics of an OPA, a second calibration serum panel was created, comprised of 20 sera collected from adults immunized with the 23-valent polysaccharide vaccine, with 150 to 500 aliquots prepared for each serum. In order to establish consensus OPA values of the 20 sera for the 13 serotypes in 13-valent PCV, the sera were tested by 4 laboratories in an international collaborative OPA study. The 007sp results of 1 laboratory deviated significantly from those obtained by the other laboratories, as well as from previously assigned values. Due to these discrepancies, the consensus values for the calibration sera were determined based on the data from the remaining laboratories. Thus, we were able to create a panel of sera with consensus opsonic values that could be used by outside laboratories to calibrate pneumococcal OPAs. Our results also confirmed findings of a previous study that normalization of OPA results significantly reduces interlaboratory variation, with normalization based on 007sp reducing variation by 43% to 74%, depending on serotype.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5944569PMC
http://dx.doi.org/10.1097/MD.0000000000010567DOI Listing

Publication Analysis

Top Keywords

calibration sera
16
sera
9
opsonic values
8
opa
8
calibration serum
8
serum panel
8
serotypes covered
8
calibration
6
serotypes
6
laboratories
6

Similar Publications

Background: Vascular calcification is highly prevalent and associated with mortality in hemodialysis patients. However, extreme splanchnic arterial calcification in calciphylaxis with poor prognosis raises questions regarding the reliability of previous vascular calcification scoring methods. Therefore, this study aimed to examine the distribution characteristics of abdominal aortic branch calcification and identify a more reliable predictor of mortality in hemodialysis patients.

View Article and Find Full Text PDF

Background: Currently, there is no mathematical model used nationally to determine the medical urgency of patients on the heart transplant waitlist in the United States. While the current organ distribution system accounts for many patient factors, a truly objective model is needed to more reliably stratify patients by their medical acuity.

Objectives: The aim of the study was to develop risk scores (Colorado Heart failure Acuity Risk Model [CHARM] score) to predict mortality in adults waitlisted for heart transplant.

View Article and Find Full Text PDF

Objectives: to construct a prediction model for clinically significant prostate cancer (csPCa) based on prostate-specific antigen (PSA) levels, digital rectal examination (DRE), and transrectal ultrasonography (TRUS).

Methods: We retrospectively analysed 1196 Asian patients who underwent transrectal ultrasound-guided biopsy (TRUSB) between June 2000 and February 2023. Patients were randomly divided into a training set of 837 cases (70%) and a validation set of 359 patients (30%).

View Article and Find Full Text PDF

Objective: To evaluate the risk factors contributing to preoperative malnutrition in elderly patients with hip fractures.

Methods: The study retrospectively analysed clinical data from 182 elderly patients aged 60 years or older with hip fractures. Nutritional status was assessed according to the Global Leadership Initiative on Malnutrition diagnostic criteria, and risk factors associated with malnutrition were identified through univariate and logistic regression analyses.

View Article and Find Full Text PDF

In this study, a mimetic fluorescence nanosensor based on a molecularly imprinted polymer was designed for the detection of amygdalin (AMG). Its characteristics and functional performance were investigated and recorded using ATR-FTIR, AFM and porosity tests. This designed sensor is considered superior to other reported techniques due to its low material consumption during both manufacturing and operation as well as its low cost and desirable performance characteristics, such as short response time, high stability and an appropriate detection limit.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!