Cardiodynamicsgram: a novel tool for monitoring cardiac function in exercise training.

J Sports Sci

c Sports Science Research Center , Zhejiang College of Sports, Hangzhou , P. R. China.

Published: November 2018

This study evaluated the feasibility of cardiodynamicsgram (CDG) for monitoring the cardiac functions of athletes and exercisers. CDG could provide an effective, simple, and economical tool for exercise training. Seventeen middle-distance race athletes aged 14-28 years old were recruited. CDG tests and blood test including creatine kinase (CK), CK-MB isoenzyme, and high-sensitivity troponin I (hsTnI) were performed before a high-intensity prolonged training, as well as 2 and 14 h after training, respectively. The CDG test result was unsatisfactory when the CK test result was used as standard. However, the accuracy of CDG test was about 80% when CK-MB and hsTnI were used as standards. Thus, CDG offers a noninvasive, simple, and economical approach for monitoring the cardiac function of athletes and exercisers during exercise training. Nonetheless, the applicability of CDG needs further investigation.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02640414.2018.1470070DOI Listing

Publication Analysis

Top Keywords

monitoring cardiac
12
exercise training
12
cardiac function
8
athletes exercisers
8
simple economical
8
cdg test
8
test result
8
cdg
7
training
5
cardiodynamicsgram novel
4

Similar Publications

Insights and Opportunities from Multimarker Evaluation of Heart Failure: Lessons from BIOSTAT-HF.

Curr Heart Fail Rep

January 2025

Division of Cardiovascular Medicine, Department of Medicine, University of California, 9394 Medical Center Drive, La Jolla, San Diego, CA, USA.

Purpose Of Review: Heart failure is a complex and heterogenous disease state that affects millions worldwide. Over recent decades, advancements in medical therapy and device implementation have significantly transformed the landscape of heart failure outcomes, while improvements in imaging modalities and greater accessibility to genome sequencing have led to increasing recognition of distinct heart failure endotypes. There is rising evidence to suggest all patients do not benefit equally from intensification of guideline directed medical therapy (GDMT).

View Article and Find Full Text PDF

Epicardial Pacemaker Lead Related Cardiac Strangulation: The Importance of Early Recognition.

Pediatr Cardiol

January 2025

Cardiothoracic Department, Children's Health Ireland at Crumlin, Dublin, Ireland.

Lead strangulation is a dangerous complication of epicardial pacemaker insertion. This complication has been increasingly highlighted lately. Our institution has recently identified four cases over the past five years.

View Article and Find Full Text PDF

Diagnostic Feasibility of Cardiac PET CT in the Evaluation of Inflammatory, Infectious, and Malignant Heart Disease.

R I Med J (2013)

February 2025

Alpert Medical School of Brown University, Department of Medicine, Division of Cardiology, Rhode Island Hospital.

Cardiac Positron Emission Tomography (PET) is a power- ful imaging tool with diverse applications in the detection and diagnosis of various cardiac conditions, including inflammatory, infectious, and neoplastic processes. Using the radiotracer 18F-fluorodeoxyglucose (18F-FDG), cardiac PET enables the identification of cardiac involvement in diseases such as sarcoidosis and severe infections affecting the heart tissue. Additionally, 18F-FDG PET is valuable in the evaluation of cardiac masses, helping to assess their metabolic activity and potential malignancy.

View Article and Find Full Text PDF

Background: Acute kidney injury (AKI) is a common postoperative complication, and hypotension may contribute. We therefore tested the primary hypothesis that individualized intraoperative blood pressure regulation reduces postoperative AKI in older surgical patients.

Methods: We enrolled patients ≥60 years old scheduled for elective major abdominal surgery with invasive arterial pressure monitoring.

View Article and Find Full Text PDF

Introduction: The 6-minute walk test (6MWT) is used to assess submaximal exercise capacity in clinical trials. Conducting the 6MWT can be challenging when patients cannot visit the clinic due to physical/travel limitations. This pilot study assessed the feasibility of conducting the 6MWT using wearable sensors for patients with transthyretin amyloid cardiomyopathy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!