A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessing sarcopenia with vastus lateralis muscle ultrasound: an operative protocol. | LitMetric

Background: Muscle ultrasound (MUS) has so far not been implemented for sarcopenia assessment in clinical geriatric practice due to allegedly low reproducibility of results in the absence of standardization of procedures. However, rigorous and standardized application of this technique yields highly reproducible results. Its application, especially if integrated with clinical evaluation and comprehensive geriatric assessment, proofs very useful for rapidly obtaining information on muscle mass and architecture.

Objective: Here, we present a standardized protocol for performing right vastus lateralis (RVL) MUS and measuring parameters of muscle size and architecture.

Methods: RVL muscle thickness (MT), fascicle length (FL), pennation angle (PA), echo-intensity (EI) and cross-sectional area (CSA) can be assessed with this protocol. A portable instrument equipped with a 5-cm long 3-11 mHz linear probe should be used with both B-mode real-time and extended-field-of-view (EFOV) techniques. Longitudinal B-mode and transverse EFOV images should be acquired during each exam, and analyzed with NIH-ImageJ software.

Conclusions: This operative protocol represents a good compromise between the feasibility of MUS in clinical settings and the need of obtaining precise measurements of muscle parameters. Future studies should verify the reproducibility of the proposed technique, and its correlation with appendicular lean mass and parameters of muscle function.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s40520-018-0958-1DOI Listing

Publication Analysis

Top Keywords

vastus lateralis
8
muscle ultrasound
8
operative protocol
8
parameters muscle
8
muscle
7
assessing sarcopenia
4
sarcopenia vastus
4
lateralis muscle
4
ultrasound operative
4
protocol
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!