Background: To date, no gold standard for the surgical treatment of femoral hernia exists. Pure tissue repair as well as mesh/plug implantation, open or laparoscopic, are the most performed methods. Nevertheless, all these techniques need sutures or mesh fixation. This implies the risk of damaging sensitive structures of the femoral area, along with complications related to tissue tear and postoperative discomfort consequent to poor quality mesh incorporation. The present retrospective multicenter case series highlights the results of femoral hernia repair procedures performed with a 3D dynamic responsive implant in a cohort of 32 patients during a mean follow up of 27 months.

Materials And Methods: Aiming to simplify the surgical procedure and reduce complications, a 3D dynamic responsive implant was delivered for femoral hernia repair, in a patient cohort. After returning the hernia sack to the abdominal cavity, the implant was simply delivered into the hernia defect where it remained, thanks to its inherent centrifugal expansion, obliterating the hernia opening without need of fixation. Postoperative pain assessment was determined using the VAS score system.

Results: The use of the 3D prosthetic device allowed for easier and faster surgical repair in a fixation free fashion. None of the typical fixation related complications occurred in the examined patients. Postoperative pain assessment with VAS score showed a very low level of pain, allowing the return of patients to normal activities in extremely reduced times. In the late postoperative period, no discomfort or chronic pain was reported.

Conclusions: Femoral hernia repair with the 3D dynamic revealed a quick and safe placement procedure. The reduced pain intensity, as well as the absence of adverse events consequent to sutures or mesh fixation, seems to be a significant benefit of the motile compliance of the device. Furthermore, this 3D prosthesis has already proven to induce an enhanced probiotic response showing ingrowth in the implant of the typical tissue components of the abdominal wall, instead of the low quality tissue ingrowth typical in conventional meshes and plugs. The highlighted features seem to represent a more physiologic and updated repair concept of femoral protrusions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijsu.2018.04.031DOI Listing

Publication Analysis

Top Keywords

femoral hernia
20
hernia repair
16
dynamic responsive
12
responsive implant
12
fixation free
8
hernia
8
repair dynamic
8
case series
8
sutures mesh
8
mesh fixation
8

Similar Publications

Sciatic hernia, a rare type of pelvic floor hernia, presents significant diagnostic and therapeutic challenges. We report the first totally extraperitoneal (TEP) repair of a sciatic hernia, which was performed in a 63-year-old woman who presented with vomiting and poor dietary intake. Computed tomography revealed a strangulated femoral hernia and an incidental herniation of the sigmoid colon through the right sciatic foramen.

View Article and Find Full Text PDF

An obturator hernia (OH) is a rare type of hernia that accounts for a very small proportion of all hernias and cases of small bowel obstruction. This condition predominantly affects older, underweight individuals, with the vast majority of patients being women. Laparotomy with simple suture closure of the defect is commonly used as surgical treatment for OH.

View Article and Find Full Text PDF

Geriatric nutritional risk index as a predictor of major postoperative complications in emergency femoral hernia patients.

BMC Surg

December 2024

Department of Hernia and Abdominal Wall Surgery, Beijing Chaoyang Hospital, Capital Medical University, Beijing, 100043, China.

Background: To evaluate the prognostic values of GNRI for major postoperative complications in emergency femoral hernia patients.

Methods: In this cross-sectional study, we enrolled 105 emergency femoral hernia patients. GNRI was calculated using preoperative body weight, height, and serum albumin.

View Article and Find Full Text PDF

Aims This study aims to analyse the type of repair and post-op outcomes for individuals who underwent surgical intervention and presented with symptomatic abdominal wall hernia as an emergency. It highlights the importance of timely elective hernia management in lowering emergency presentations and any related complications. Background Abdominal wall hernias are common surgical conditions that can present electively or as emergencies, with emergency cases being associated with higher complication rates.

View Article and Find Full Text PDF

Introduction: Groin discomfort is one of the most common presenting complaints in health care and often requires ultrasound to detect hernias. However, such singular emphasis leads to over diagnosing hernia and other significant aetiologies in and around the groin are overlooked.

Topic Description: The article elaborates on the key areas a sonographer needs to focus on and presents a range of conditions responsible for groin pain other than hernia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!