A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simple Chip Electrophoresis Titration of Neutralization Boundary with EDTA Photocatalysis for Distance-Based Sensing of Melamine in Dairy Products. | LitMetric

AI Article Synopsis

  • Melamine is often added to dairy products in developing countries to falsely increase protein content, leading to safety concerns.
  • A new portable distance-based sensor has been developed that uses chip electrophoretic titration and photocatalysis to accurately detect melamine levels in dairy products.
  • The sensor is highly sensitive, cost-effective, easy to use, and can provide results in under 15 minutes, making it suitable for on-site quality evaluation of dairy products.

Article Abstract

Melamine was sometimes adulterated to dairy products for false protein content increase in developing countries. However, a portable sensor has not been developed for on-spot determination of melamine in dairy products yet. Herein, a distance-based sensor was advanced for the quantification of melamine in dairy products based on chip electrophoretic titration (ET) of moving neutralization boundary (NB) and EDTA photocatalysis. In the chip sensor, EDTA, HO, and leucomalachite green (LMG) were added in the anode well. Under UV light, EDTA photocatalyzes HO and colorless LMG as HO and color malachite green (MG) with one positive charge. When applying an electric field, the MG in the anode well migrated into the channel and was neutralized with the base in the channel, resulting in colorless MG-OH and NB. If the melamine-content dairy sample was added into the EDTA-HO-LMG system, HO reacts with melamine, leading to the decrease of MG. Thus, the higher the melamine content in dairy products, the shorter the distance of NB migration under the given time, implying a distance-based sensor of melamine. A series of experiments manifested the validity of ET-NB sensor for detection of melamine. Moreover, the results revealed the numerous merits of ET-NB sensor, such as good selectivity, high sensitivity (LOD down to 0.20 μM for milk and 0.10 μM for infant formula vs the FDA safety limits of 20 μM for milk and 8.0 μM for infant formula), good repeatability and recoveries (87-108% for milk, 90-107% for formula). Particularly, the cell phone-like sensor was portable, simple (no any pretreatment), rapid (within 15 min), as well as low cost, to evaluate the quality of dairy products. The developed sensor has great potential in on-spot detection of melamine in dairy products as well as other analytes, at which we are testing in our lab.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.8b00543DOI Listing

Publication Analysis

Top Keywords

dairy products
28
melamine dairy
16
melamine
9
neutralization boundary
8
boundary edta
8
edta photocatalysis
8
dairy
8
sensor
8
distance-based sensor
8
anode well
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!