A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[The assessment of factors influencing occurrence of adequate interventions of cardiac resynchronization therapy with cardioverter-defibrillator implanted in primary prevention of sudden cardiac death in dilative cardiomyopathy and percentage of biventricular pacing]. | LitMetric

Unlabelled: The assessment of factors influencing occurrence of adequate interventions of cardiac resynchronization therapy with cardioverter-defibrillator implanted in primary prevention of sudden cardiac death in dilative cardiomyopathy and percentage of biventricular pacing.

Introduction: The function of cardiac resynchronization therapy with cardioverter-defibrillator (CRT-D) is to treat heart failure (HF) and to treat ventricular arrhythmia, if it occurs, with adequate intervention.

Aim: The aim of the study was to find predictors of adequate interventions and in how many patients biventricular pacing percentage decreases during the follow-up.

Material And Methods: The study comprised of 228 patients (178 M, mean age 66±10, 31-89 years) with implanted CRTD. The following data were analyzed: age, sex, presence of dilative cardiomyopathy, diabetes mellitus, lowered creatinine clearance, atrial fibrillation (AF), LVEF, NYHA class, adequate interventions, number of arrhythmias, pharmacotherapy modifications, device parameters and mortality.

Results: Mean ejection fraction of the left ventricle was 20.9±6.4, (10.0- 35%). During the mean follow up of 770±490 days in 84 (37%) patients adequate interventions of the device occurred. The adequate interventions concerned mainly patients with diabetes mellitus (HR 2.95), in NYHA class II, with paroxysmal atrial fibrillation (HR 2.15). In 39 patients (17%) the mean percentage of biventricular pacing was below 90%, and in 18 (8%) below 85%.

Conclusions: Diabetes mellitus, NYHA class II, paroxysmal atrial fibrillation have significantly increased the risk of adequate intervention. The most common causes of loss of biventricular pacing were: inappropriate AV delay, supraventricular arrhythmias and premature ventricular complexes. A significant correlation between low biventricular pacing percentage and the occurrence of supraventricular arrhythmias and adequate interventions was observed.

Download full-text PDF

Source

Publication Analysis

Top Keywords

adequate interventions
28
biventricular pacing
16
cardiac resynchronization
12
resynchronization therapy
12
therapy cardioverter-defibrillator
12
dilative cardiomyopathy
12
percentage biventricular
12
diabetes mellitus
12
atrial fibrillation
12
nyha class
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!