Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This research aimed to quantitatively bioanalyze 6-mercaptopurine (6-MP), 6-methylmercaptopurine (6-MMP), and 6-thioguanosine-5′-monophosphate (6-TGMP) in dried blood spots (DBS) prepared from a small volume of acute lymphoblastic leukemia (ALL) patients. Analytes on the DBS card were extracted using 90% methanol with 5-fluorouracil (5-FU) as an internal standard. Analytical separation was performed on a Waters Acquity UPLC BEH AMIDA column of 1.7 μm (2.1 × 100 mm) with a mobile phase mixture of 0.2% formic acid in water and 0.1% formic acid in acetonitrile-methanol, with gradient elution and a flow rate of 0.2 mL/min. Mass detection of 6-MP, 6-MMP, 6-TGMP, and 5-FU showed / values of 153.09 > 119.09, 167.17 > 126.03, 380.16 > 168.00, and 129.09 > 42.05, respectively. This DBS method had a run time of 5 min and yielded a linear calibration curve over a range of 25.5⁻1020 ng/mL for 6-MP, 6-MMP, and 6-TGMP. Analyte analysis in 22 of 24 ALL patients showed that the measured value of 6-TGMP as an active metabolite was in the range of 29⁻429 pmol/8 × 10⁸ erythrocytes. Five of 22 patients had concentrations in a therapeutic range, which indicates that the treatment is effective, while 17 of 24 patients had concentrations below the therapeutic range, which indicates that a treatment dose adjustment is needed. The measured value of 6-MMP, an inactive metabolite, was in the range of 28⁻499 pmol/8 × 10⁸ erythrocytes, which includes concentrations below the hepatotoxic range. The method employed here can thus be effectively utilized to support therapeutic drug monitoring.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6027686 | PMC |
http://dx.doi.org/10.3390/scipharm86020018 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!