Background: The vertical jump is used to estimate sports performance capabilities and physical fitness in children, elderly, non-athletic and injured individuals. Different jump techniques and measurement tools are available to assess vertical jump height and peak power; however, their use is limited by access to laboratory settings, excessive cost and/or time constraints thus making these tools oftentimes unsuitable for field assessment. A popular field test uses the Vertec and the Sargent vertical jump with countermovement; however, new low cost, easy to use tools are becoming available, including the iOS mobile application (app). The purpose of this study was to assess the reliability of the relative to values obtained by the Vertec for the Sargent stand and reach vertical jump (VJ) test.
Methods: One hundred and thirty-five healthy participants aged 18-39 years (94 males, 41 females) completed three maximal Sargent VJ with countermovement that were simultaneously measured using the Vertec and the . Jump heights were quantified for each jump and peak power was calculated using the Sayers equation. Four separate ICC estimates and their 95% confidence intervals were used to assess reliability. Two analyses (with jump height and calculated peak power as the dependent variables, respectively) were based on a single rater, consistency, two-way mixed-effects model, while two others (with jump height and calculated peak power as the dependent variables, respectively) were based on a single rater, absolute agreement, two-way mixed-effects model.
Results: Moderate to excellent reliability relative to the degree of consistency between the Vertec and values was found for jump height (ICC = 0.813; 95% CI [0.747-0.863]) and calculated peak power (ICC = 0.926; 95% CI [0.897-0.947]). However, poor to good reliability relative to absolute agreement for VJ height (ICC = 0.665; 95% CI [0.050-0.859]) and poor to excellent reliability relative to absolute agreement for peak power (ICC = 0.851; 95% CI [0.272-0.946]) between the Vertec and values were found; Vertec VJ height, and thus, Vertec calculated peak power values, were significantly higher than those calculated from values ( < 0.0001).
Discussion: The app may provide a reliable measure of vertical jump height and calculated peak power in multiple field and laboratory settings without the need of costly equipment such as force plates or Vertec. The reliability relative to degree of consistency between the Vertec and app was moderate to excellent. However, the reliability relative to absolute agreement between Vertec and values contained significant variation (based on CI values), thus, it is recommended that either the or the Vertec be used to assess VJ height in repeated measures within subjects' designs; these measurement tools should not be considered interchangeable within subjects or in group measurement designs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5912202 | PMC |
http://dx.doi.org/10.7717/peerj.4669 | DOI Listing |
Sci Rep
January 2025
Department of Electrical and Electronics, Faculty of Engineering, Alberoni University, Kapisa, Afghanistan.
This study first proposes an innovative method for optimizing the maximum power extraction from photovoltaic (PV) systems during dynamic and static environmental conditions (DSEC) by applying the horse herd optimization algorithm (HHOA). The HHOA is a bio-inspired technique that mimics the motion cycles of an entire herd of horses. Next, the linear active disturbance rejection control (LADRC) was applied to monitor the HHOA's reference voltage output.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Department of Food Science and Technology, College of Agriculture, Isfahan University of Technology, Isfahan 84156-83111, Iran; ONIRIS - GEPEA (UMR CNRS 6144), Site de la Géraudière CS 82225, 44322, Nantes cedex 3, France.
This study explores the innovative combined effects of alkaline isolation with ultrasound pretreatment on the physicochemical properties of acorn (Quercus brantii) starch. The optimal pH for maximizing the yield of alkaline-isolated acorn starch (AAS) was determined, followed by comparison with alkaline-isolated defatted acorn starch (ADAS), ultrasound-pretreated acorn starch (UAS), and ultrasound-pretreated defatted acorn starch (UDAS). The results demonstrated substantial improvements in yield and purity, with the highest yield (68.
View Article and Find Full Text PDFBr J Hosp Med (Lond)
January 2025
Department of Sports Arts, Hebei Sport University, Shijiazhuang, Hebei, China.
A novel exercise protocol for cardiac rehabilitation aerobic (CRA) has been developed by Hebei Sport University, demonstrating efficacy in patients with coronary heart disease (CHD). The objective of this study was to evaluate the impact of CRA on precise cardiac rehabilitation (CR) for CHD patients presenting with stable angina pectoris. The study cohort comprised patients with stable angina who were categorized into three groups: the CRA group (n = 35), the power bicycles (PB) group (n = 34), and the control group (n = 43).
View Article and Find Full Text PDFNutrients
January 2025
School of Sport Science, Beijing Sport University, Beijing 100084, China.
Background: Both listening to music during warm-up and consuming caffeine before exercise have been independently shown to enhance athletic performance. However, the potential synergistic effects of combining these strategies remain largely unexplored. To date, only two studies have reported additional benefits to combining music during warm-up with a caffeine dose of 3 mg/kg on taekwondo-specific performance tasks.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Mechanical Engineering, University of Utah, Salt Lake City, UT 84112, USA.
Field implementations of fully underground sensor networks face many practical challenges that have limited their overall adoption. Power management is a commonly cited issue, as operators are required to either repeatedly excavate batteries for recharging or develop complex underground power infrastructures. Prior works have proposed wireless inductive power transfer (IPT) as a potential solution to these power management issues, but misalignment is a persistent issue in IPT systems, particularly in applications involving moving vehicles or obscured (e.