Purpose: Health state utility values are derived from preference-based measurements and are useful in calculating quality-adjusted life years (QALYs), which is a metric commonly used in cost-effectiveness studies. The purpose of this study was to convert the Achilles Tendon Rupture Score (ATRS) to the preference-based European Quality of Life-5 Dimension Questionnaire (EQ-5D) by estimating the relationship between the two scores using mapping.

Methods: Data were collected from a randomised controlled trial, where 100 patients were treated either surgically or non-surgically for Achilles tendon rupture. Forty-three and forty-four patients in surgical group and non-surgical group completed the ATRS and the EQ-5D alongside each other during follow-up at three time points. Different models of the relationship between the ATRS and the EQ-5D were developed and analysed based on direct mapping and cross-validation. The model with the lowest mean absolute error was observed as the one with the best fit.

Results: Among the competing models, mapping based on using a combination of the ATRS items four, five, and six associated with limitation due to pain, during activities of daily living and when walking on uneven ground, produced the best predictor of the EQ-5D score.

Conclusions: The present study provides a mapping algorithm to enable the derivation of utility values directly from the ATRS. This approach makes it feasible for researchers, as well as medical practitioners, to obtain preference-based values in clinical studies or settings where only the ATRS is being administered. The algorithm allows for the calculation of QALYs for use in cost-effectiveness analyses, making it valuable in the study of acute Achilles tendon ruptures.

Level Of Evidence: II.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6154025PMC
http://dx.doi.org/10.1007/s00167-018-4954-yDOI Listing

Publication Analysis

Top Keywords

achilles tendon
16
tendon rupture
12
rupture score
8
utility values
8
atrs eq-5d
8
atrs
6
mapping
5
eq-5d
5
mapping functions
4
functions health-related
4

Similar Publications

Background: The Achilles tendon is one of the most frequent sites of tendinopathy in both healthy and pathological subjects. An innovative approach for the quantitative assessment of the Achilles tendon structure, named Ultrasound Tissue Characterization (UTC), has recently been developed. However, no previous study performed the UTC-based assessment of the tendon structure in rheumatologic patients affected by insertional Achilles tendinopathy.

View Article and Find Full Text PDF

Purpose We aimed to report an innovative single-site endoscopic surgery for soft tissue lesions performed at our center. Methods All patients who underwent soft tissue surgery were reviewed. All consecutive patients who underwent single-site endoscopic surgery between September 2019 and March 2024 were included in the study.

View Article and Find Full Text PDF

A motion-responsive injectable lubricative hydrogel for efficient Achilles tendon adhesion prevention.

Mater Today Bio

February 2025

Basic Research Key Laboratory of General Surgery for Digital Medicine, Affiliated Hospital of Hebei University, Baoding, 071000, China.

Achilles tendon is a motor organ that is prone to tissue adhesion during its repair process after rupture. Therefore, developing motion-responsive and anti-adhesive biomaterials is an important need for the repair of Achilles tendon rupture. Here, we report an injectable lubricative hydrogel (ILH) based on hydration lubrication mechanism, which is also motion-responsive based on sol-gel reversible transmission.

View Article and Find Full Text PDF

Objective: The purpose of this study was to investigate the timing and mode of failure of metallic screw-type suture anchors used to attach artificial tendons to bone in an New Zealand White rabbit model.

Study Design: Metal suture anchors with braided composite sutures of varying sizes (United States Pharmacopeia (USP) size 1, 2, or 5) were used to secure artificial tendons replacing both the Achilles and tibialis cranialis tendons in 12 female New Zealand White rabbits. Artificial tendons were implanted either at the time of (immediate replacement,  = 8), or four/five weeks after (delayed replacement,  = 4) resection of the biological tendon.

View Article and Find Full Text PDF

Fabrication of a micropatterned shape-memory polymer patch with L-DOPA for tendon regeneration.

Biomater Sci

January 2025

Department of Nanobiomedical Science & BK21 FOUR micropatterned shape-memory NBM Global Research Center for Regenerative Medicine, Dankook University, Cheonan 31116, Republic of Korea.

A scaffold design for tendon regeneration has been proposed, which mimics the microstructural features of tendons and provides appropriate mechanical properties. We synthesized a temperature-triggered shape-memory polymer (SMP) using the ring-opening polymerization of polycaprolactone (PCL) with polyethylene glycol (PEG) as a macroinitiator. We fabricated a micropatterned patch using SMP capillary force lithography, which mimicked a native tendon, for providing physical cues and guiding effects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!